Bifurcation and Large-Signal Stability Analysis of Three-Phase Voltage Source Converter Under Grid Voltage Dips
被引:130
作者:
Huang, Meng
论文数: 0引用数: 0
h-index: 0
机构:
Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R ChinaWuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
Huang, Meng
[1
]
Peng, Yu
论文数: 0引用数: 0
h-index: 0
机构:
Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R ChinaWuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
Peng, Yu
[1
]
Tse, Chi K.
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Elect & Informat Engn, Hong Kong, Hong Kong, Peoples R ChinaWuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
Tse, Chi K.
[2
]
Liu, Yushuang
论文数: 0引用数: 0
h-index: 0
机构:
Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R ChinaWuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
Liu, Yushuang
[1
]
Sun, Jianjun
论文数: 0引用数: 0
h-index: 0
机构:
Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R ChinaWuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
Sun, Jianjun
[1
]
Zha, Xiaoming
论文数: 0引用数: 0
h-index: 0
机构:
Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R ChinaWuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
Zha, Xiaoming
[1
]
机构:
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Hong Kong Polytech Univ, Dept Elect & Informat Engn, Hong Kong, Hong Kong, Peoples R China
Three-phase voltage source converters (VSCs) are commonly used as power flow interface in ac/dc hybrid power systems. The ac power grid suffers from unpredictable short-circuit faults and power flow fluctuations, causing undesirable grid voltage dips. The voltage dips may last for a short time or a long duration, and vary the working conditions of VSCs. Due to their nonlinear characteristics, VSCs may enter abnormal operating mode in response to voltage dips. In this paper, the transient response of three-phase VSCs under practical grid voltage dips is studied and a catastrophic bifurcation phenomenon is identified in the system. The converter will exhibit an irreversible instability after the dips. The expanded magnitude of ac reactive current may cause catastrophic consequence for the system. A full-order eigenvalue analysis and a reduced-order mixed-potential-theory-based analysis are adopted to reveal the physical origin of the large-signal instability phenomenon. The key parameters of the system are identified and the boundaries of instability are located. The bifurcation phenomenon and a set of design-oriented stability boundaries in some chosen parameter space are verified by cycle-by-cycle simulations and experimental measurement on a practical grid-connected VSC prototype.
机构:
Univ Western Australia, Dept Elect & Informat Engn, Crawley, WA 6009, AustraliaUniv Western Australia, Dept Elect & Informat Engn, Crawley, WA 6009, Australia
Lu, HHC
;
Tse, CK
论文数: 0引用数: 0
h-index: 0
机构:Univ Western Australia, Dept Elect & Informat Engn, Crawley, WA 6009, Australia
机构:
Univ Western Australia, Dept Elect & Informat Engn, Crawley, WA 6009, AustraliaUniv Western Australia, Dept Elect & Informat Engn, Crawley, WA 6009, Australia
Lu, HHC
;
Tse, CK
论文数: 0引用数: 0
h-index: 0
机构:Univ Western Australia, Dept Elect & Informat Engn, Crawley, WA 6009, Australia