The new wave of ion-selective electrodes

被引:119
作者
Pretsch, Erno [1 ]
机构
[1] ETH, Organ Chem Lab, CH-8093 Zurich, Switzerland
基金
美国国家卫生研究院;
关键词
ion-selective electrode; lower limit of detection; selectivity; trace measurement;
D O I
10.1016/j.trac.2006.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During the last decade, the capabilities of potentiometric analysis have changed fundamentally in that the lower limit of detection (LOD) of ion-selective electrodes (ISEs) has improved by a factor of up to one million and the discrimination factor of interferences from ions by up to one billion. These spectacular improvements are related to the control of ion fluxes through the ion-selective membrane. Nowadays, ISEs can be used for trace measurements in environmental samples. Furthermore, by reducing the volume of the samples, the LOD in terms of the amount of analytes has been reduced to the attomole range. This is promising for bioanalysis using metal nanoparticle labels. Other recent progress includes the excellent fundamental understanding of the working mechanism, the introduction of a novel kind of calibration procedure that reduces the demands on signal stability and reproducibility, and the advent of pulsed amperometric methods. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 85 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]   A phase boundary potential model for apparently "twice-Nernstian" responses of liquid membrane ion-selective electrodes [J].
Amemiya, S ;
Bühlmann, P ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :445-454
[3]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[4]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[5]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[6]  
Bakker E, 2004, TALANTA, V63, P3, DOI 10.1016/j.talanta.2003.10.006
[7]   SELECTIVITY OF POLYMER MEMBRANE-BASED ION-SELECTIVE ELECTRODES - SELF-CONSISTENT MODEL DESCRIBING THE POTENTIOMETRIC RESPONSE IN MIXED ION SOLUTIONS OF DIFFERENT CHARGE [J].
BAKKER, E ;
MERUVA, RK ;
PRETSCH, E ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3021-3030
[8]   Ion-selective electrodes based on two competitive ionophores for determining effective stability constants of ion-carrier complexes in solvent polymer membranes [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :295-302
[9]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[10]   Ionophore-based membrane electrodes: new analytical concepts and non-classical response mechanisms [J].
Bakker, E ;
Meyerhoff, ME .
ANALYTICA CHIMICA ACTA, 2000, 416 (02) :121-137