The new wave of ion-selective electrodes

被引:119
作者
Pretsch, Erno [1 ]
机构
[1] ETH, Organ Chem Lab, CH-8093 Zurich, Switzerland
基金
美国国家卫生研究院;
关键词
ion-selective electrode; lower limit of detection; selectivity; trace measurement;
D O I
10.1016/j.trac.2006.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During the last decade, the capabilities of potentiometric analysis have changed fundamentally in that the lower limit of detection (LOD) of ion-selective electrodes (ISEs) has improved by a factor of up to one million and the discrimination factor of interferences from ions by up to one billion. These spectacular improvements are related to the control of ion fluxes through the ion-selective membrane. Nowadays, ISEs can be used for trace measurements in environmental samples. Furthermore, by reducing the volume of the samples, the LOD in terms of the amount of analytes has been reduced to the attomole range. This is promising for bioanalysis using metal nanoparticle labels. Other recent progress includes the excellent fundamental understanding of the working mechanism, the introduction of a novel kind of calibration procedure that reduces the demands on signal stability and reproducibility, and the advent of pulsed amperometric methods. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 85 条
[11]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[12]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[13]   FABRICATION AND EVALUATION OF MEMBRANES AS SPECIFIC ELECTRODES FOR CALCIUM IONS [J].
BLOCH, R ;
SHATKAY, A ;
SAROFF, HA .
BIOPHYSICAL JOURNAL, 1967, 7 (06) :865-&
[14]   Conducting polymer-based solid-state ion-selective electrodes [J].
Bobacka, J .
ELECTROANALYSIS, 2006, 18 (01) :7-18
[15]   Fluorous bulk membranes for potentiometric sensors with wide selectivity ranges:: Observation of exceptionally strong ion pair formation [J].
Boswell, PG ;
Bühlmann, P .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (25) :8958-8959
[16]  
Bourgeois JP, 1998, ANGEW CHEM INT EDIT, V37, P2118, DOI 10.1002/(SICI)1521-3773(19980817)37:15<2118::AID-ANIE2118>3.0.CO
[17]  
2-9
[18]   Tracing of selective [J].
Buck, RP ;
Lindner, E .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :88A-97A
[19]   Studies of potential generation across membrane sensors at interfaces and through bulk [J].
Buck, RP ;
Lindner, E .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) :257-266
[20]  
Bühlmann P, 1999, ELECTROANAL, V11, P687, DOI 10.1002/(SICI)1521-4109(199907)11:10/11<687::AID-ELAN687>3.0.CO