Laboratory investigations of the response of Brewer-Mast ozonesondes to tropospheric ozone

被引:16
作者
Tarasick, DW
Davies, J
Anlauf, K
Watt, M
Steinbrecht, W
Claude, HJ
机构
[1] Environm Canada, Downsview, ON, Canada
[2] Deutsch Wetterdienst German Weather Serv, Meteorol Observ Hohenpeissenberg, D-82383 Hohenpeissenberg, Germany
来源
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES | 2002年 / 107卷 / D16期
关键词
ozone; ozonesonde; Brewer-Mast; troposphere; calibration; response;
D O I
10.1029/2001JD001167
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The Brewer-Mast ozonesonde was used at Canadian stations from 1966 until 1980, when the Canadian network switched to the electrochemical concentration cell sonde. While the sondes appear to agree relatively well in the stratosphere, there is an evident discrepancy of 10-20% in tropospheric measurements [e.g., Tarasick et al., 1995, Figure 4]. Comparison of Brewer-Mast sondes with a calibrated ozone source yields some interesting insight into this discrepancy. Sonde response is strongly dependent on the preflight preparation procedures employed. Although sondes prepared via procedures introduced in the 1980s [Claude et al., 1987] perform quite well, when prepared according to the procedures used in Canada in the 1970s, Brewer-Mast sondes indicate 10-30% lower ozone than the calibrator. The following points are noted in particular: (1) a new Brewer-Mast sonde shows a large (similar to15%) increase in sensitivity between successive experiments; (2) especially at low (<100 ppb) O-3 levels, the response even of previously flown sondes increases slowly with time; and (3) sondes show an additional slow increase of response with time that is apparently caused by ozone reactions with the phosphate buffer. The overall response curve indicated by 1, 2, and 3 implies that after correction to the observed total ozone, the earlier part of a flight would yield values that are too low, while the latter part would be too high. By applying a varying ozone input, simulating the typical variation in absolute ozone concentration experienced by a sonde in flight, we show that this can explain both the average correction factor (1.255) for the Canadian Brewer-Mast record and the 10-20% discrepancy in tropospheric measurements.
引用
收藏
页数:10
相关论文
共 33 条
[1]  
Attmannspacher A., 1970, BER DTSCH WETTERDIEN, V120, P1
[2]  
Attmannspacher A., 1981, BER DTSCH WETTERDIEN, V157, P1
[3]  
BEEKMAN M, 1995, J ATMOS CHEM, V19, P259
[4]   INTERCOMPARISON CAMPAIGN OF VERTICAL OZONE PROFILES INCLUDING ELECTROCHEMICAL SONDES OF ECC AND BREWER-MAST TYPE-A GROUND-BASED UV-DIFFERENTIAL ABSORPTION LIDAR [J].
BEEKMANN, M ;
ANCELLET, G ;
MEGIE, G ;
SMIT, HGJ ;
KLEY, D .
JOURNAL OF ATMOSPHERIC CHEMISTRY, 1994, 19 (03) :259-288
[5]   IMPROVED NEUTRAL BUFFERED POTASSIUM-IODIDE METHOD FOR OZONE IN AIR [J].
BERGSHOEFF, G ;
LANTING, RW ;
PROP, JMG ;
REYNDERS, HFR .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :541-546
[6]   THE OXFORD-KEW OZONE SONDE [J].
BREWER, AW ;
MILFORD, JR .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1960, 256 (1287) :470-495
[7]  
CLAUDE H, 1987, 17 WMO GLOB OZ RES M
[8]  
CLAUDE H, 1996, ATMOSPHERIC OZONE, P21
[9]   THE IODINE IODIDE INTERACTION [J].
DAVIES, M ;
GWYNNE, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1952, 74 (11) :2748-2752
[10]   Comparison of ozone profiles obtained with Brewer-Mast and Z-ECC sensors during simultaneous ascents [J].
De Backer, H ;
De Muer, D ;
De Sadelaer, G .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1998, 103 (D16) :19641-19648