Diagnosis of pancreatic tumors by endoscopic ultrasound-guided fine-needle aspiration

被引:67
作者
Ardengh, Jose Celso
Lopes, Cesar Vivian
Pereira de Lima, Luiz Felipe
de Oliveira, Juliano Rodrigues
Venco, Filadelfio
Santo, Giulio Cesare
Pimenta Modena, JoseLuiz
机构
[1] USP, Echoendoscopy Unit, Julho Hosp 9, BR-91410000 Porto Alegre, RS, Brazil
[2] USP, Pathol Unit, Julho Hosp 9, BR-91410000 Porto Alegre, RS, Brazil
[3] USP, Ribeirao Preto Med Sch, BR-91410000 Porto Alegre, RS, Brazil
关键词
diagnosis; endoscopic ultrasound; fine needle-aspiration biopsy; pancreas cancer; pancreatic disease; sampling;
D O I
10.3748/wjg.v13.i22.3112
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To evaluate the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for pancreatic solid tumors larger or smaller than 3 cm, and cystic lesions. METHODS: From January/1997 to December/2006, 611 patients with pancreatic tumors were subjected to EUS-FNA. The final diagnosis was obtained either by surgery (356 cases) or after a mean clinical follow-up of 11.8 mo in the remaining patients. RESULTS: There were 405 solid tumors, 189 cystic lesions and 17 mixed. Pancreatic specimens for cytological assessment were successfully obtained by EUS-FNA in 595 (97.4%) cases. There were 352 (57.6%) malignancies and 259 (42.4%) benign tumors. Among the malignancies, pancreatic adenocarcinomas accounted for 67% of the lesions. Overall, the sensitivity, specificity positive and negative predictive values, and accuracy of EUS-FNA were, respectively, 78.4%, 99.2%, 99.3%, 77.2% and 87.2%. Specifically for solid tumors, the same parameters for neoplasms larger and smaller than 3 cm were, respectively, 78.8% vs 82.4%, 100% vs 98.4%, 100% vs 99%, 54.8% vs 74.1% and 83.1% vs 87.8%. For cystic lesions, the values were, respectively, 72.2%, 99.3%, 97.5%, 91% and 92.2%. CONCLUSION: EUS-FNA can be used to sample pancreatic tumors in most patients. Even though the negative predictive value is inadequate for large solid tumors, the results are rather good for small solid tumors, especially concerning the sensitivity, negative predictive value and diagnostic accuracy. Among all pancreatic lesions, EUS-FNA for cystic lesions can reveal the best negative predictive value and diagnostic accuracy, both higher than 90%. (c) 2007 The WJG Press. All rights reserved.
引用
收藏
页码:3112 / 3116
页数:5
相关论文
共 34 条
  • [11] Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses
    Harewood, GC
    Wiersema, MJ
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (06) : 1386 - 1391
  • [12] Endosonography-guided biopsy of mediastinal and pancreatic tumors
    Hunerbein, M
    Dohmoto, M
    Haensch, W
    Schlag, PM
    [J]. ENDOSCOPY, 1998, 30 (01) : 32 - 36
  • [13] Assessment of EUS for diagnosing, staging, and determining resectability of pancreatic cancer: a review
    Hunt, GC
    Faigel, DO
    [J]. GASTROINTESTINAL ENDOSCOPY, 2002, 55 (02) : 232 - 237
  • [14] ITOL T, 2005, ENDOSCOPY, V37, P362
  • [15] Role of endoscopic ultrasound in the diagnosis of patients with solid pancreatic masses
    Kahl, S
    Malfertheiner, P
    [J]. DIGESTIVE DISEASES, 2004, 22 (01) : 26 - 31
  • [16] Liu K, 1998, DIAGN CYTOPATHOL, V19, P70, DOI 10.1002/(SICI)1097-0339(199807)19:1<70::AID-DC15>3.0.CO
  • [17] 2-5
  • [18] Endoscopic ultrasound-guided fine needle aspiration of the pancreas: cytomorphological evaluation with emphasis on adequacy assessment, diagnostic criteria and contamination from the gastrointestinal tract
    Mitsuhashi, T
    Ghafari, S
    Chang, CY
    Gu, M
    [J]. CYTOPATHOLOGY, 2006, 17 (01) : 34 - 41
  • [19] ENDOSCOPIC ULTRASONOGRAPHY IN DIAGNOSIS AND STAGING OF PANCREATIC-CANCER
    NAKAIZUMI, A
    UEHARA, H
    IISHI, H
    TATSUTA, M
    KITAMURA, T
    KURODA, C
    OHIGASHI, H
    ISHIKAWA, O
    OKUDA, S
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1995, 40 (03) : 696 - 700
  • [20] ENDOSCOPIC ULTRASONOGRAPHY IN THE DIAGNOSIS AND STAGING OF PANCREATIC ADENOCARCINOMA - RESULTS OF A PROSPECTIVE-STUDY WITH COMPARISON TO ULTRASONOGRAPHY AND CT SCAN
    PALAZZO, L
    ROSEAU, G
    GAYET, B
    VILGRAIN, V
    BELGHITI, J
    FEKETE, F
    PAOLAGGI, JA
    [J]. ENDOSCOPY, 1993, 25 (02) : 143 - 150