Miniaturization in sample treatment for environmental analysis

被引:79
作者
Ramos, L
Ramos, JJ
Brinkman, UAT
机构
[1] CSIC, Inst Organ Chem, Dept Instrumentat Anal & Environm, E-28006 Madrid, Spain
[2] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
sample preparation; miniaturization; environmental analysis; trace analysis; micro-contaminants;
D O I
10.1007/s00216-004-2906-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increasing demand for faster, more cost-effective and environmentally friendly analytical methods is a major incentive to improve the classical procedures used for sample treatment in environmental analysis. In most classical procedures, the use of rapid and powerful instrumental techniques for the final separation and detection of the analytes contrasts with the time-consuming and usually manual methods used for sample preparation, which slows down the total analytical process. The efforts made in this field in the past ten years have led to the adaptation of existing methods and the development of new techniques to save time and chemicals, and improve overall performance. One route has been to develop at-line or on-line and, frequently, automated systems. In these approaches, miniaturization has been a key factor in designing integrated analytical systems to provide higher sample throughput and/or unattended operation. Selected examples of novel developments in the field of miniaturized sample preparation for environmental analysis are used to evaluate the merits of the various techniques on the basis of published data on real-life analyses of trace-level organic pollutants. Perspectives and trends are briefly discussed.
引用
收藏
页码:119 / 140
页数:22
相关论文
共 216 条
[11]  
2-4
[12]  
Ban E, 2001, ELECTROPHORESIS, V22, P2173, DOI 10.1002/1522-2683(20017)22:11<2173::AID-ELPS2173>3.0.CO
[13]  
2-8
[14]  
Barcelo D., 1997, Trace Determination of Pesticides and Their Degradation Products in Water
[15]   ISOLATION OF DRUG RESIDUES FROM TISSUES BY SOLID-PHASE DISPERSION [J].
BARKER, SA ;
LONG, AR ;
SHORT, CR .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :353-361
[16]   Applications of matrix solid-phase dispersion in food analysis [J].
Barker, Steven A. .
Journal of Chromatography A, 2000, 880 (01) :63-68
[17]   Matrix solid-phase dispersion [J].
Barker, SA .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :115-127
[18]   Analytical methods for biological monitoring of exposure to pesticides: a review [J].
Barr, DB ;
Needham, LL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2) :5-29
[19]   Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry [J].
Basheer, C ;
Balasubramanian, R ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) :11-20
[20]   Stir bar sorptive extraction-thermal desorption-capillary gas chromatography-mass spectrometry applied to the analysis of polychlorinated biphenyls in human sperm [J].
Benijts, T ;
Vercammen, J ;
Dams, R ;
Tuan, HP ;
Lambert, W ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :137-142