Fluorescent Carrier Ampholytes Assay for Portable, Label-Free Detection of Chemical Toxins in Tap Water

被引:18
作者
Bercovici, M. [2 ]
Kaigala, G. V. [1 ]
Backhouse, C. J. [3 ]
Santiago, J. G. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Aeronaut & Astronaut, Stanford, CA 94305 USA
[3] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2V4, Canada
关键词
ISOTACHOPHORESIS; SEPARATION; ELECTROPHORESIS; SYSTEMS;
D O I
10.1021/ac902526g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a novel method for fluorescence-based indirect detection of analytes and demonstrate its use for label-free detection of chemical toxins in a hand-held device. We fluorescently label a mixture of low-concentration carrier ampholytes and introduce it into an isotachophoresis (ITP) separation. The carrier ampholytes provide a large number of fluorescent species with a wide range of closely spaced effective electrophoretic mobilities. Analytes focus under ITP and displace subsets of these carrier ampholytes. The analytes are detected indirectly and quantified by analyzing the gaps in the fluorescent ampholyte signal. The large number (on the order of 1000) of carrier ampholytes enables detection of a wide range of analytes, requiring little a priori knowledge of their electrophoretic properties. We discuss the principles of the technique and demonstrate its, use in the detection of various analytes using a standard microscope system, We then present the integration of the technique into a self-contained hand-held device and demonstrate detection of chemical toxins (2-nitrophenol and 2,4,6-trichlorophenol) in tap water, with no sample preparation steps.
引用
收藏
页码:1858 / 1866
页数:9
相关论文
共 30 条
[1]   ISOTACHOPHORESIS OF PROTEINS [J].
ACEVEDO, F .
JOURNAL OF CHROMATOGRAPHY, 1989, 470 (02) :407-414
[2]  
[Anonymous], National Recommended Water Quality Criteria
[3]   DETERMINATION OF PHENOLS BY HPLC DOWN TO PPT LEVELS [J].
BALDWIN, DA ;
DEBOWSKI, JK .
CHROMATOGRAPHIA, 1988, 26 :186-190
[4]   An integrated CMOS high voltage supply for lab-on-a-chip systems [J].
Behnam, M. ;
Kaigala, G. V. ;
Khorasani, M. ;
Marshall, P. ;
Backhouse, C. J. ;
Elliott, D. G. .
LAB ON A CHIP, 2008, 8 (09) :1524-1529
[5]   Method for Analyte Identification Using Isotachophoresis and a Fluorescent Carrier Ampholyte Assay [J].
Bercovici, M. ;
Kaigala, G. V. ;
Santiago, J. G. .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :2134-2138
[6]  
BOCEK P, 1978, J CHROMATOGR, V156, P323
[7]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[8]   Imaging and Quantification of Isotachophoresis Zones Using Nonfocusing Fluorescent Tracers [J].
Chambers, Robert D. ;
Santiago, Juan G. .
ANALYTICAL CHEMISTRY, 2009, 81 (08) :3022-3028
[9]   DETERMINATION OF SUBSTANCES AT LOW CONCENTRATIONS IN COMPLEX-MIXTURES BY ISOTACHOPHORESIS WITH COLUMN COUPLING [J].
EVERAERTS, FM ;
VERHEGGEN, TPEM ;
MIKKERS, FEP .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :21-38
[10]   Capillary isotachophoretic analysis of serum lipoproteins using a carrier ampholyte as spacer ion [J].
Inano, K ;
Tezuka, S ;
Miida, T ;
Okada, M .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :708-716