Enzyme Containing Redox Polymer Networks for Biosensors or Biofuel Cells: A Photochemical Approach

被引:46
作者
Bunte, Christine [1 ]
Prucker, Oswald [1 ]
Koenig, Tobias [1 ]
Ruehe, Juergen [1 ]
机构
[1] Univ Freiburg, IMTEK, Dept Microsyst Engn, D-79110 Freiburg, Germany
关键词
GLUCOSE-OXIDASE; HYDROGEL MICROSTRUCTURES; CHARGE-TRANSPORT; FILMS; FERROCENE; MONOLAYERS; ELECTRON; ATTACHMENT; SURFACES; SENSORS;
D O I
10.1021/la9037183
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A photochemical approach to the generation of (microstructured) redox hydrogels NOM incorporated enzymes is presented and evaluated with respect to its potential in biosensor and biofuel cell applications. For this, poly(dimethylacrylamide) polymers containing both electroactive ferrocene moieties and photoreactive benzophenone groups are synthesized and deposited as thin films on electrode surfaces. Upon short irradiation with UV light, the polymer layer cross links and becomes firmly adhered to the glassy carbon electrodes. If glucose oxidase is mixed into the polymer solution prior to coating, then glucose-oxidizing electrodes with very high catalytic current responses are obtained. The influence of multivalent ions and proteins on the performance or the electrocatalytic films is studied. It is found that the interaction between bivalent HPO42- and the oxidized redox moieties can shorten the lifetime of the redox electrodes significantly whereas the same electrodes are quite stable in the presence of monovalent ions and the reduced form of the mediator. Coating a thin, covalently attached poly(dimethylacrylamide) protective layer onto the redox polymer networks can greatly reduce the adsorption of proteins onto the surfaces and improve the long-term stability of the electrodes in physiological environments. Because the adsorption of proteins onto unprotected surfaces is one of the major causes of bioelectrode failure. this aspect is expected to contribute to the design of more biostable sensors and fuel cells.
引用
收藏
页码:6019 / 6027
页数:9
相关论文
共 50 条
[1]   Ultraviolet photolithographic development of polyphosphazene hydrogel microstructures for potential use in microarray biosensors [J].
Allcock, HR ;
Phelps, MVB ;
Barrett, EW ;
Pishko, MV ;
Koh, WG .
CHEMISTRY OF MATERIALS, 2006, 18 (03) :609-613
[2]   Biofuel Cell Controlled by Enzyme Logic Systems [J].
Amir, Liron ;
Tam, Tsz Kin ;
Pita, Marcos ;
Meijler, Michael M. ;
Alfonta, Lital ;
Katz, Evgeny .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (02) :826-832
[3]   ELECTRONEUTRALITY COUPLING OF ELECTRON HOPPING BETWEEN LOCALIZED SITES WITH ELECTROINACTIVE COUNTERION DISPLACEMENT .1. POTENTIAL-STEP PLATEAU CURRENTS [J].
ANDRIEUX, CP ;
SAVEANT, JM .
JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (23) :6761-6767
[4]   Electrochemical characteristics of glucose oxidase immobilized in poly(quinone) redox polymers [J].
Arai, G ;
Shoji, K ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 591 (01) :1-6
[5]  
BARD AJ, 2001, ELECTROCHEMICAL METH, pCH5
[6]   Enzymatic biofuel cells for Implantable and microscale devices [J].
Barton, SC ;
Gallaway, J ;
Atanassov, P .
CHEMICAL REVIEWS, 2004, 104 (10) :4867-4886
[7]   Transition metal cation and phosphate anion electrochemical recognition in water by new polyaza ferrocene macrocyclic ligands [J].
Beer, PD ;
Chen, Z ;
Drew, MGB ;
Johnson, AOM ;
Smith, DK ;
Spencer, P .
INORGANICA CHIMICA ACTA, 1996, 246 (1-2) :143-150
[8]   Electrochemical and optical sensing of anions by transition metal based receptors [J].
Beer, PD ;
Cadman, J .
COORDINATION CHEMISTRY REVIEWS, 2000, 205 :131-155
[9]   Sources of instability of 'wired' enzyme anodes in serum: urate and transition metal ions [J].
Binyamin, G ;
Chen, T ;
Heller, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 500 (1-2) :604-611
[10]   Biocatalytic fuel cells: A comparison of surface pre-treatments for anchoring biocatalytic redox films on electrode surfaces [J].
Boland, Susan ;
Jenkins, Peter ;
Kavanagh, Paul ;
Leech, Donal .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 626 (1-2) :111-115