Role of ligand purity in separations of alkaline earth metals as arsenazo I complexes by capillary zone electrophoresis

被引:11
作者
Macka, M [1 ]
Paull, B [1 ]
Bogan, DP [1 ]
Haddad, PR [1 ]
机构
[1] Univ Tasmania, Dept Chem, Hobart, Tas 7001, Australia
基金
澳大利亚研究理事会;
关键词
complexation; ligand purity; alkaline earth metals; metal complexes; arsenazo I; metal cations;
D O I
10.1016/S0021-9673(97)00868-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the separation of metal ions by capillary electrophoresis in the form of kinetically labile complexes formed through the incorporation of an auxiliary complexing ligand into the background electrolyte (BGE), it has been shown that the purity of this auxiliary complexing ligand can play a crucial role in the selectivity and efficiency of the resultant separations. Using the separation of alkaline earth metals as complexes with the metallochromic ligand arsenate I as a model system, the effects of the addition of low concentrations of simulated impurities, in the form of various metal ions and competing ligands, were studied, Additions of Fe-III at low micromolar levels to a BGE containing 1 mM arsenate I resulted in severe peak tailing. The addition of the competing ligands diethylenetriaminepentaacetic acid (DTPA) or arsenate III, at a molar ratio as low as 1:1000 to arsenate I, also caused substantial peak broadening and altered the separation selectivity. The practical implications of the above results for the separation of metals as labile complexes, using capillary zone electrophoresis (CZE) systems similar to the above, are discussed. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 38 条
[11]   MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF HEMATOPORPHYRIN, PROTOPORPHYRIN AND THEIR COPPER AND ZINC-COMPLEXES [J].
KIYOHARA, C ;
SAITOH, K ;
SUZUKI, N .
JOURNAL OF CHROMATOGRAPHY, 1993, 646 (02) :397-403
[12]   CAPILLARY ELECTROPHORESIS COUPLED ONLINE WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ELEMENTAL SPECIATION [J].
LIU, Y ;
LOPEZAVILA, V ;
ZHU, JJ ;
WIEDERIN, DR ;
BECKERT, WF .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2020-2025
[13]   Linearity evaluation in absorbance detection: The use of light-emitting diodes for on-capillary detection in capillary electrophoresis [J].
Macka, M ;
Andersson, P ;
Haddad, PR .
ELECTROPHORESIS, 1996, 17 (12) :1898-1905
[14]   SEPARATION OF SOME METALLOCHROMIC LIGANDS BY CAPILLARY ZONE ELECTROPHORESIS AND MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
MACKA, M ;
HADDAD, PR ;
BUCHBERGER, W .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :493-501
[15]   Determination of barium and strontium by capillary zone electrophoresis using an electrolyte containing sulfonazo III [J].
Macka, M ;
Paull, B ;
Andersson, P ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :303-310
[16]  
MACKA M, 1996, P INT ION CHROM S II
[17]  
MACKA M, 1996, P CHROM 96 SYDN AUST
[18]  
MACKA M, 1997, IN PRESS ELECTROPHOR
[19]  
MACKA M, 1997, UNPUB J CHROMATOGR A
[20]   SEPARATION AND SENSITIVE DETERMINATION OF METAL-IONS BY CAPILLARY ZONE ELECTROPHORESIS WITH 2-(5-NITRO-2-PYRIDYLAZO)-5-(N-PROPYL-N-SULFOPROPYLAMINO)PHENOL [J].
MOTOMIZU, S ;
MORI, N ;
KUWABARA, M ;
OSHIMA, M .
ANALYTICAL SCIENCES, 1994, 10 (01) :101-103