A low-cost and flexible double-crystal monochromator for an x-ray beamline

被引:6
作者
Hwang, CS
Lin, FY
Lee, CH
Yu, KL
Hsieh, CH
Tseng, PK
Lin, JT
Pong, WF
机构
[1] Synchrotron Radiat Res Ctr, Hsinchu 30077, Taiwan
[2] Natl Tsing Hua Univ, Dept Engn & Syst Sci, Hsinchu 30043, Taiwan
[3] Natl Taiwan Normal Univ, Dept Phys, Taipei 117, Taiwan
[4] Tamkang Univ, Dept Phys, Taipei, Taiwan
[5] Natl Taiwan Univ, Dept Phys, Taipei, Taiwan
关键词
D O I
10.1063/1.1148755
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work designs and implements an inexpensive and simple double-crystal monochromator, which yields a high performance ar a bending magnet x-ray beamline. A primary feature of the proposed monochromator is that the offset between the incident and monochromatic exit of the x-ray beam can be adjusted to cover a wide energy range with a short X-Y traveling stroke. Such a short range of X-Y strokes fan reduce the monochromator's overall size and, also, increase the stability of motions, Meanwhile, in this monochromator, instead of using a complicated hardware linkage mechanism, a software program is developed to effectively control the X-Y stage for positioning the second crystal in a fixed exit configuration, alleviating mechanic motion errors to maintain the parallelism of the two crystals. The entire software control mechanical linkage offers a relatively inexpensive and simple assembly monochromator that is mon flexible than the commercially available one. (C) 1998 American Institute of Physics. [S0034-6748(98)00403-1].
引用
收藏
页码:1230 / 1235
页数:6
相关论文
共 19 条
[11]   SAGITTALLY FOCUSING DOUBLE-CRYSTAL MONOCHROMATOR WITH CONSTANT EXIT BEAM HEIGHT AT THE PHOTON FACTORY [J].
MATSUSHITA, T ;
ISHIKAWA, T ;
OYANAGI, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :377-379
[12]  
MILLS D, 1980, REV SCI INSTRUM, V51, P509
[13]   A FIXED EXIT SAGITTAL FOCUSING MONOCHROMATOR UTILIZING BENT SINGLE-CRYSTALS [J].
MILLS, DM ;
HENDERSON, C ;
BATTERMAN, BW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :356-359
[14]  
MUTATA T, 1992, REV SCI INSTRUM, V63, P1309
[15]  
PONG WF, 1990, THESIS U NOTRE DAME
[16]   A CLOSED-LOOP FEEDBACK-SYSTEM FOR SYNCHROTRON RADIATION DOUBLE CRYSTAL MONOCHROMATORS [J].
RAMANATHAN, M ;
ENGBRETSON, M ;
MONTANO, PA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :471-474
[17]   HIGH-FLUX, UHV-COMPATIBLE, WATER-COOLED DOUBLE CRYSTAL MONOCHROMATOR FOR BEAM LINE X9 AT NSLS [J].
ROSENBAUM, G ;
ROCK, L ;
SULLIVAN, M ;
KHALID, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :475-478
[18]   DESIGN, CONSTRUCTION AND TEST-RESULTS OF A SLITLESS, HIGH-POWER, HIGH-RESOLUTION DOUBLE CRYSTAL X-RAY MONOCHROMATOR FOR SYNCHROTRON RADIATION [J].
VANDERHOEK, MJ ;
WERNER, W ;
VANZUYLEN, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :190-193
[19]   DOUBLE-CRYSTAL MONOCHROMATOR BEAM LINE ON THE ALADDIN 1-GEV STORAGE RING [J].
YANG, BX ;
MIDDLETON, FH ;
OLSSON, BG ;
BANCROFT, GM ;
CHEN, JM ;
SHAM, TK ;
TAN, K ;
WALLACE, DJ .