Effects of temperature and humidity on the cell performance and resistance of a phosphoric acid doped polybenzimidazole fuel cell

被引:92
作者
Chen, Chen-Yu [1 ]
Lai, Wei-Hsiang [1 ]
机构
[1] Natl Cheng Kung Univ, Inst Aeronaut & Astronaut, Tainan 701, Taiwan
关键词
Proton exchange membrane fuel cell (PEMFC); Polybenzimidazole (PBI); Phosphoric acid; Operating temperature; Operating humidity; Electrochemical impedance spectroscopy (EIS); POLYMER ELECTROLYTE MEMBRANE; CONTACT RESISTANCE; IMPEDANCE SPECTROSCOPY; COMPOSITE MEMBRANES; HYDROGEN-PRODUCTION; WATER; PREDICTION; OPERATION; METHANOL; PEMFC;
D O I
10.1016/j.jpowsour.2010.05.057
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Performance and electrochemical impedance spectroscopy (EIS) tests were performed at different temperatures and humidity levels to understand the effects of temperature and humidity on the performance and resistance of a PBI/H3PO4 fuel cell. The results of the performance tests indicated that increasing the temperature significantly improved the cell performance. In contrast, no improvement was observed when the gas humidity was increased. On the other hand, the EIS results showed that the membrane resistance was reduced for elevated temperatures. This development can be interpreted by the increase in membrane conductivity, as reflected by the Arrhenius equation. As the formation of H4P2O7 and the self-dehydration of H3PO4 start around 130-140 degrees C, in PBI, they increase the membrane resistance at temperatures that are higher than 130 degrees C. In addition, the membrane resistance was reduced for elevated gas humidity levels. This is because an increase in humidity leads to an increase of the membrane hydration level. The resistance of the catalyst kinetics mainly contributes to the charge transfer resistance. However, under certain conditions, the interfacial charge transfer resistance is also important. It was concluded that the gas diffusion is the main contributor to the mass transfer resistance under dry conditions while it is the gas concentration under humid conditions. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:7152 / 7159
页数:8
相关论文
共 61 条
[1]   PARTIAL OXIDATION OF METHANE TO SYNTHESIS GAS-USING CARBON-DIOXIDE [J].
ASHCROFT, AT ;
CHEETHAM, AK ;
GREEN, MLH ;
VERNON, PDF .
NATURE, 1991, 352 (6332) :225-226
[2]   Proton conduction in acid doped polybenzimidazole [J].
Bouchet, R ;
Siebert, E .
SOLID STATE IONICS, 1999, 118 (3-4) :287-299
[3]   Measuring moisture sorption and diffusion kinetics on proton exchange membranes using a gravimetric vapor sorption apparatus [J].
Burnett, Daniel J. ;
Garcia, Armando R. ;
Thielmann, Frank .
JOURNAL OF POWER SOURCES, 2006, 160 (01) :426-430
[4]   The design and cost analysis of a portable PEMFC UPS system [J].
Chang, Hsin-Ping ;
Chou, Chao-Ling ;
Chen, Yong-Song ;
Hou, Tien-I ;
Weng, Biing-Jyh .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (03) :316-322
[5]   Planar array stack design aided by rapid prototyping in development of air-breathing PEMFC [J].
Chen, Chen-Yu ;
Lai, Wei-Hsiang ;
Weng, Biing-Jyh ;
Chuang, Huey-Jan ;
Hsieh, Ching-Yuan ;
Kung, Chien-Chih .
JOURNAL OF POWER SOURCES, 2008, 179 (01) :147-154
[6]   Electrical test methods for on-line fuel cell ohmic resistance measurement [J].
Cooper, K. R. ;
Smith, M. .
JOURNAL OF POWER SOURCES, 2006, 160 (02) :1088-1095
[7]   The interaction of water vapors with H3PO4 imbibed electrolyte based on PBI/polysulfone copolymer blends [J].
Daletou, Maria K. ;
Kallitsis, Joannis K. ;
Voyiatzis, George ;
Neophytides, Stylianos G. .
JOURNAL OF MEMBRANE SCIENCE, 2009, 326 (01) :76-83
[8]   A method for determining anode and cathode impedances of a direct methanol fuel cell running on a load [J].
Diard, JP ;
Glandut, N ;
Landaud, P ;
Le Gorrec, B ;
Montella, C .
ELECTROCHIMICA ACTA, 2003, 48 (05) :555-562
[9]   Water and phosphoric acid uptake of poly [2,5-benzimidazole] (ABPBI) membranes prepared by low and high temperature casting [J].
Diaz, Liliana A. ;
Abuin, Graciela C. ;
Corti, Horacio R. .
JOURNAL OF POWER SOURCES, 2009, 188 (01) :45-50
[10]   Model based PEM fuel cell state-of-health monitoring via ac impedance measurements [J].
Fouquet, N. ;
Doulet, C. ;
Nouillant, C. ;
Dauphin-Tanguy, G. ;
Ould-Bouamama, B. .
JOURNAL OF POWER SOURCES, 2006, 159 (02) :905-913