Total hip arthroplasty with shelf grafts using uncemented cups - A long-term follow-up study

被引:50
作者
Morsi, E [1 ]
Garbuz, D [1 ]
Gross, AE [1 ]
机构
[1] UNIV TORONTO,MT SINAI HOSP,DIV ORTHOPAED SURG,TORONTO,ON M5G 1X5,CANADA
关键词
shelf autografts; shelf allografts; cementless cups; leg-length discrepancy;
D O I
10.1016/S0883-5403(96)80164-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A series of 33 hips treated with cementless cups and structural autograft or allograft were reviewed at a minimum follow-up period of 5 years. Seventeen hips received a shelf autograft during primary hip arthroplasty and 16 received an allograft al revision. In the hips receiving autografts, the average pre operative hip score was 45.1 and the score al final review was 87.5, whereas in the revisions reconstructed with allografts, the average preoperative hip score was 44.4 and the score at final review was 82. Overall, only 2 of 33 hips were considered failures, giving a success rate of 94% at an average follow-up period of 6.6 years. Leg-length discrepancy greater than 2 cm was seen in 27 of 33 hips, and at final review only 4 of 33 hips had a leg-length discrepancy greater than 2 cm. All grafts united to host-bone. Resorption, when seen, was minor, with only three grafts showing moderate resorption. Our data support the use of cementless cups with structural allografts and autografts, provided the graft supports less than 50% of the cup.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 19 条
[11]  
Paavilainen T, 1993, CLIN ORTHOP RELAT R, V297, P71
[12]   REVISION OF THE ACETABULAR COMPONENT WITHOUT CEMENT AFTER TOTAL HIP-ARTHROPLASTY - 3-YEAR TO 6-YEAR FOLLOW-UP [J].
PADGETT, DE ;
KULL, L ;
ROSENBERG, A ;
SUMNER, DR ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) :663-673
[13]  
Paprosky W G, 1994, J Arthroplasty, V9, P33, DOI 10.1016/0883-5403(94)90135-X
[14]  
PAPROSKY WG, 1994, CLIN ORTHOP RELAT R, V298, P147
[15]   PROXIMAL PLACEMENT OF THE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY - A LONG-TERM FOLLOW-UP-STUDY [J].
RUSSOTTI, GM ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (04) :587-592
[16]   THE HARRIS-GALANTE POROUS-COATED ACETABULAR COMPONENT WITH SCREW FIXATION - RADIOGRAPHIC ANALYSIS OF 83 PRIMARY HIP REPLACEMENTS AT A MINIMUM OF 5 YEARS [J].
SCHMALZRIED, TP ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08) :1130-1139
[17]  
Silber D A, 1990, J Arthroplasty, V5, P231, DOI 10.1016/S0883-5403(08)80077-0
[18]   REVISION OF THE ACETABULAR COMPONENT WITH AN UNCEMENTED HARRIS-GALANTE POROUS-COATED PROSTHESIS [J].
TANZER, M ;
DRUCKER, D ;
JASTY, M ;
MCDONALD, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :987-994
[19]  
1979, AM ASS TISSUE BANKS, V3, P2