A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments

被引:73
作者
Hülsmann, M [1 ]
Gressmann, G [1 ]
Schäfers, F [1 ]
机构
[1] Univ Gottingen, Dept Operat Dent Prevent Dent & Periodontol, Zentrum ZMK, D-37075 Gottingen, Germany
关键词
automated root canal preparation; FlexMaster; HERO; 642; Ni-Ti instruments;
D O I
10.1046/j.1365-2591.2003.00664.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare several parameters of root canal preparation using two different rotary nickel-titanium (Ni-Ti) instruments: FlexMaster (VDW, Munich, Germany) and HERO 642 (Micro-Mega, Besancon, France). Methodology Fifty extracted human mandibular molars with root canal curvatures between 20 and 408 were embedded into a muffler e system. All root canals were prepared to size 45 using a high-torque motor with two different Ni-Ti instruments, FlexMaster and HERO 642. In both groups, irrigation was performed with 2 mL NaOCl (3%) after each instrument size. RC-Prep (Premier, Philadelphia, USA) was used as a chelating agent with each instrument. The following parameters were evaluated: straightening of curved root canals, postoperative root canal diameter, working safety (file fractures, perforations, apical blockages, loss of working length), cleaning ability and working time. Statistical analysis was performed using the Wilcoxon's test (P<0.05) for straightening and Fishers's exact test (P<0.05) for comparison of cross-sections, contact between pre- and postoperative diameter, root canal cleanliness and working time. Results Both Ni-Ti systems maintained the curvature well: the mean degree of straightening was 0.6degrees for FlexMaster and 0.5degrees for HERO 642. One file was fractured with the FlexMaster system, but further procedural incidents were not recorded. Following preparation with FlexMaster, 18% of the root canals had a round diameter, 53% an oval diameter and 29% an irregular diameter; HERO 642 preparations resulted in a round diameter in 25%, oval shape in 47% and irregular cross-sections in 28% of the cases. Mean working time was shorter for HERO 642 (66.0 s) than for FlexMaster (71.1 s). Cleanliness of the root canal walls was investigated under the SEM using 5-score indices for debris and smear layer. For debris, HERO 642 and FlexMaster achieved 73 and 70% scores of 1 and 2, respectively. The results for smear layer were similar: HERO 642 and FlexMaster achieved 33 and 26% scores of 1 and 2, respectively. Significant differences between the two systems were not detected for any of the parameters evaluated. Conclusions Both systems respected original root canal curvature well and were safe. Both systems failed to remove debris and smear layer in the majority of the cases.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 34 条
[1]  
American Association of Endodontists, 1994, GLOSS CONT TERM END
[2]   Effect of experience on quality of canal preparation with rotary nickel-titanium files [J].
Baumann, MA ;
Roth, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (06) :714-718
[3]   A METHODOLOGY FOR EVALUATION OF ROOT-CANAL INSTRUMENTATION [J].
BRAMANTE, CM ;
BERBERT, A ;
BORGES, RP .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :243-245
[4]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[5]  
Bryant ST, 1998, INT ENDOD J, V31, P282
[6]  
Gambarini G, 2000, ENDOD DENT TRAUMATOL, V16, P95
[7]   A reconstructed computerized tomographic comparison of Ni-Ti rotary GT™ files versus traditional instruments in canals shaped by novice operators [J].
Gluskin, AH ;
Brown, DC ;
Buchanan, LS .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (06) :476-484
[8]  
H?lsmann M, 2000, ENTWICKLUNG METHODIK
[9]  
HERBST U, 2002, THESIS GOTTINGEN
[10]   An improved technique for the evaluation of root canal preparation [J].
Hülsmann, M ;
Gambal, A ;
Bahr, R .
JOURNAL OF ENDODONTICS, 1999, 25 (09) :599-602