Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity

被引:229
作者
Brage, Soren
Ekelund, Ulf
Brage, Niels
Hennings, Mark A.
Froberg, Karsten
Franks, Paul W.
Wareham, Nicholas J.
机构
[1] MRC Epidemiol Unit, Elsie Widdowson Lab, Cambridge CB1 9NL, England
[2] Univ So Denmark, Inst Sport Sci & Clin Biomech, Odense, Denmark
[3] Univ Cambridge, Dept Pure Math & Math Stat, Sydney Sussex Coll, Cambridge, MA USA
[4] Umea Univ Hosp, Genet Epidemiol & Clin Res Grp, Dept Hlth & Clin Med, Med Sect, Umea, Sweden
基金
英国医学研究理事会;
关键词
energy expenditure; monitoring; heart rate variability; accelerometry; movement sensor;
D O I
10.1152/japplphysiol.00092.2006
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Combining accelerometry with heart rate ( HR) monitoring may improve precision of physical activity measurement. Considerable variation exists in the relationships between physical activity intensity ( PAI) and HR and accelerometry, which may be reduced by individual calibration. However, individual calibration limits feasibility of these techniques in population studies, and less burdensome, yet valid, methods of calibration are required. We aimed to evaluate the precision of different individual calibration procedures against a reference calibration procedure: a ramped treadmill walking-running test with continuous measurement of PAI by indirect calorimetry in 26 women and 25 men [ mean ( SD): 35 ( 9) yr, 1.69 ( 0.10) m, 70 ( 14) kg]. Acceleration ( along the longitudinal axis of the trunk) and HR were measured simultaneously. Alternative calibration procedures included treadmill testing without calorimetry, submaximal step and walk tests with and without calorimetry, and nonexercise calibration using sleeping HR and gender. Reference accelerometry and HR models explained > 95% of the between-individual variance in PAI ( P < 0.001). This fraction dropped to 73 and 81%, respectively, for accelerometry and HR models calibrated with treadmill tests without calorimetry. Step-test calibration captured 62 - 64% ( accelerometry) and 68% ( HR) of the variance between individuals. Corresponding values were 63 - 76% and 59 - 61% for walk-test calibration. There was only little benefit of including calorimetry during step and walk calibration for HR models. Nonexercise calibration procedures explained 54% ( accelerometry) and 30% ( HR) of the between-individual variance. In conclusion, a substantial proportion of the between-individual variance in relationships between PAI, accelerometry, and HR is captured with simple calibration procedures, feasible for use in epidemiological studies.
引用
收藏
页码:682 / 692
页数:11
相关论文
共 67 条
[1]  
ANDREWS RB, 1971, AM J CLIN NUTR, V24, P1139
[2]  
AVONS P, 1988, EUR J CLIN NUTR, V42, P185
[3]   AN APPROACH TO ARTIFACT IDENTIFICATION - APPLICATION TO HEART PERIOD DATA [J].
BERNTSON, GG ;
QUIGLEY, KS ;
JANG, JF ;
BOYSEN, ST .
PSYCHOPHYSIOLOGY, 1990, 27 (05) :586-598
[4]   ECG artifacts and heart period variability: Don't miss a beat! [J].
Berntson, GG ;
Stowell, JR .
PSYCHOPHYSIOLOGY, 1998, 35 (01) :127-132
[5]   PHYSICAL-FITNESS AND ALL-CAUSE MORTALITY - A PROSPECTIVE-STUDY OF HEALTHY-MEN AND WOMEN [J].
BLAIR, SN ;
KOHL, HW ;
PAFFENBARGER, RS ;
CLARK, DG ;
COOPER, KH ;
GIBBONS, LW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1989, 262 (17) :2395-2401
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Prediction of peak oxygen uptake in men using pulmonary and hemodynamic variables during exercise [J].
Bogaard, HJ ;
Woltjer, HH ;
van Keimpema, ARJ ;
Postmus, PE ;
de Vries, PMJM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (03) :701-705
[8]   Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living [J].
Brage, S ;
Brage, N ;
Ekelund, U ;
Luan, J ;
Franks, PW ;
Froberg, K ;
Wareham, NJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (05) :517-524
[9]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[10]   Reliability and validity of the combined heart rate and movement sensor Actiheart [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wareham, NJ .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (04) :561-570