Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET

被引:99
作者
Baete, K
Nuyts, J
Van Laere, K
Van Paesschen, W
Ceyssens, S
De Ceuninck, L
Gheysens, O
Kelles, A
Van den Eynden, J
Suetens, P
Dupont, P
机构
[1] Katholieke Univ Leuven, UZ Gasthuisberg, Dept Nucl Med, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Dept Neurol, B-3000 Louvain, Belgium
[3] Katholieke Univ Leuven, ESAT PSI, Lab Med Image Comp, B-3000 Louvain, Belgium
关键词
iterative reconstruction; partial volume; positron emission tomography; spill-over correction;
D O I
10.1016/j.neuroimage.2004.04.041
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
FDG-PET contributes to the diagnosis and management of neurological diseases. In some of these diseases, pathological gray matter (GM) areas may have a reduced FDG uptake. Detection of these regions can be difficult and some remain undiscovered using visual assessment. The main reason for this detection problem is the relatively small thickness of GM compared to the spatial resolution of PET, known as the partial volume effect. We have developed an anatomy-based maximum-a-posteriori reconstruction algorithm (A-MAP) which corrects for this effect during the reconstruction using segmented magnetic resonance (MR) data. Monte-Carlo based 3-D brain software phantom simulations were used to investigate the influence of the strength of anatomy-based smoothing in GM, the influence of misaligned MR data, and the effect of local segmentation errors. A human observer study was designed to assess the detection performance of A-MAP versus post-smoothed maximum-likelihood (ML) reconstruction. We demonstrated the applicability of A-MAP using real patient data. The results for A-MAP showed improved recovery values and robustness for local segmentation errors. Misaligned MR data reduced the recovery values towards those obtained by post-smoothed ML, for small registration errors. In the human observer study, detection accuracy of hypometabolic regions was significantly improved using A-MAP, compared to post-smoothed ML (P<0.004). The patient study confirmed the applicability of A-MAP in clinical practice. Conclusion: A-MAP is a promising technique for voxel-based partial volume correction of FDG-PET of the human brain. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:305 / 317
页数:13
相关论文
共 31 条
  • [11] REGULARIZED EMISSION IMAGE-RECONSTRUCTION USING IMPERFECT SIDE INFORMATION
    FESSLER, JA
    CLINTHORNE, NH
    ROGERS, WL
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1464 - 1471
  • [12] Measuring the thickness of the human cerebral cortex from magnetic resonance images
    Fischl, B
    Dale, AM
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (20) : 11050 - 11055
  • [13] LROC analysis of detector-response compensation in SPECT
    Gifford, HC
    King, MA
    Wells, RG
    Hawkins, WG
    Narayanan, MV
    Pretorius, PH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 463 - 473
  • [14] BAYESIAN RECONSTRUCTION OF FUNCTIONAL IMAGES USING ANATOMICAL INFORMATION AS PRIORS
    GINDI, G
    LEE, M
    RANGARAJAN, A
    ZUBAL, IG
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 670 - 680
  • [15] ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA
    HUDSON, HM
    LARKIN, RS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 601 - 609
  • [16] Positron emission tomography metabolic data corrected for cortical atrophy using magnetic resonance imaging
    Labbe, C
    Froment, JC
    Kennedy, A
    Ashburner, J
    Cinotti, L
    [J]. ALZHEIMER DISEASE & ASSOCIATED DISORDERS, 1996, 10 (03) : 141 - 170
  • [17] Expectation maximization reconstruction of positron emission tomography images using anatomical magnetic resonance information
    Lipinski, B
    Herzog, H
    Kops, ER
    Oberschelp, W
    MullerGartner, HW
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 129 - 136
  • [18] Multimodality image registration by maximization of mutual information
    Maes, F
    Collignon, A
    Vandermeulen, D
    Marchal, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 187 - 198
  • [19] CORRECTION OF PET DATA FOR PARTIAL VOLUME EFFECTS IN HUMAN CEREBRAL-CORTEX BY MR IMAGING
    MELTZER, CC
    LEAL, JP
    MAYBERG, HS
    WAGNER, HN
    FROST, JJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 561 - 570
  • [20] Meyer C R, 1997, Med Image Anal, V1, P195, DOI 10.1016/S1361-8415(97)85010-4