A corneal model for slit-scanning elevation topography

被引:24
作者
Cairns, G
Collins, A
McGhee, CNJ [1 ]
机构
[1] Univ Auckland, Fac Med & Hlth Sci, Discipline Ophthalmol, Auckland 1, New Zealand
[2] Univ Auckland, Fac Sci, Dept Optometry & Vis Sci, Auckland 1, New Zealand
关键词
cornea; model; slit-scanning; topography; videokeratography;
D O I
10.1046/j.1475-1313.2003.00107.x
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Computerised videokeratography is increasing in sophistication and accuracy. The Orbscan II Videokeratographer combines the advantages of Placido derived and slit-scanning derived topography, to acquire shape information on the posterior surface of the cornea. The purpose of this paper is to construct a model of slit-scanning elevation topography and highlight potential sources of variation in this methodology. Ray tracing calculations were performed on a defined, theoretical, spherical model to obtain a pachymetric measurement. These calculations were tested by comparing the pachymetry measurement derived from the model, over a refractive index shift from 1.376 to 1.400 with the pachymetry measurement obtained by Orbscan II, of a human eye, with an identical alteration in refractive index. The two methods of measurement differed by only 0.157 mum, suggesting that the model is a good representation of slit-scanning elevation topography, and that refractive index variations have only a minimal effect on Orbscan II pachymetry measurement.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 23 条
[1]
Measuring anterior chamber depth with the Orbscan Topography System [J].
Auffarth, GU ;
Tetz, MR ;
Biazid, Y ;
Volcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1351-1355
[2]
Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis [J].
Baek, TM ;
Lee, KH ;
Kagaya, F ;
Tomidokoro, A ;
Amano, S ;
Oshika, T .
OPHTHALMOLOGY, 2001, 108 (02) :317-320
[3]
*BAUSCH LOMB SURG, 2000, ORBSC PRES
[4]
Accuracy of Orbscan II slit-scanning elevation topography [J].
Cairns, G ;
McGhee, CNJ ;
Collins, MJ ;
Owens, H ;
Gamble, GD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2181-2187
[5]
Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes [J].
Chakrabarti, HS ;
Craig, JP ;
Brahma, A ;
Malik, TY ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1823-1828
[6]
Dausch D, 2000, J REFRACT SURG, V16, P13
[7]
Giessler S, 2001, J REFRACT SURG, V17, P385
[8]
Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures [J].
Iskander, NG ;
Penno, EA ;
Peters, NT ;
Gimbel, HV ;
Ferensowicz, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (05) :681-685
[9]
KLYCE SD, 1998, CORNEA, P3
[10]
Treatment of myopia and myopic astigmatism by customized laser in situ keratomileusis based on corneal topography [J].
Knorz, MC ;
Neuhann, T .
OPHTHALMOLOGY, 2000, 107 (11) :2072-2076