Initial stability of fully and partially cemented femoral stems

被引:36
作者
Claes, L
Fiedler, S
Ohnmacht, M
Duda, GN
机构
[1] Univ Ulm, Inst Unfallchirurg Forsch & Biomech, D-89081 Ulm, Germany
[2] Humboldt Univ, Virchow Klinikum, Abt Unfallchirurg & Wiederherstellungschirurg, D-13353 Berlin, Germany
关键词
total hip replacement; initial stability; prosthesis design; mechanical testing;
D O I
10.1016/S0268-0033(00)00044-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Objective. To test the initial stability of a newly designed partially cemented femoral stem in comparison with a fully cemented conventional stem. Design. An in vitro study to determine the interface motion between femoral stem and bone as a response to loading. Background The aim of the new prosthesis design is a proximal load transfer by a defined partial cement fixation in the proximal femur region and a slim prosthesis stem in the distal region. Before a clinical study can be started, the new stem has to show an initial stability comparable to that of fully cemented prostheses. Method Six paired fresh cadaveric femora were used for the testing of the new partially cemented stem (Option 3000, Mathys Orthopaedics, Bettlach, Switzerland) and a fully cemented stein (Weber Shaft, AlloPro, Baar, Swizerland). Under cyclic loading up to 1600 N hip joint forces, the interface motion between implants and bone was measured at six locations. Results. Bath stems showed uncritical interface motions below 43 mum. However, the Option 3000 stem exhibited significantly smaller motions in the proximal region and slightly larger movements in the distal regions than the Weber prosthesis. Conclusions. The new type of partially cemented stem provided a comparable initial stability to the fully cemented Weber prosthesis.
引用
收藏
页码:750 / 755
页数:6
相关论文
共 16 条
[1]
Bachus KN, 1999, CLIN ORTHOP RELAT R, P248
[2]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[3]
BLAHA JD, 1991, TECHNIQUES ORTHOP, V6, P80
[4]
Three-dimensional primary stability of cementless femoral stems [J].
Buhler, DW ;
Berlemann, U ;
Lippuner, K ;
Jaeger, P ;
Nolte, LP .
CLINICAL BIOMECHANICS, 1997, 12 (02) :75-86
[5]
Recent results from the CP-PACS collaboration [J].
Burkhalter, R .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 73 :3-15
[6]
CHARNLEY J, 1965, J Bone Joint Surg Br, V47, P56
[7]
A QUANTITATIVE-EVALUATION OF PERIPROSTHETIC BONE-REMODELING AFTER CEMENTLESS TOTAL HIP-ARTHROPLASTY [J].
ENGH, CA ;
MCGOVERN, TF ;
BOBYN, JD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1009-1020
[8]
RELATIVE MOTION OF HIP STEMS UNDER LOAD - AN IN-VITRO STUDY OF SYMMETRICAL, ASYMMETRICAL, AND CUSTOM ASYMMETRICAL DESIGNS [J].
HUA, J ;
WALKER, PS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (01) :95-103
[9]
MALONEY WJ, 1989, CLIN ORTHOP RELAT R, P129
[10]
DEFINITION OF ENDOPROSTHETIC LOOSENING - COMPARISON OF ARTHROGRAPHY, SCINTIGRAPHY AND ROENTGEN STEREOPHOTOGRAMMETRY IN PROSTHETIC HIPS [J].
MJOBERG, B ;
BRISMAR, J ;
HANSSON, LI ;
PETTERSSON, H ;
SELVIK, G ;
ONNERFALT, R .
ACTA ORTHOPAEDICA SCANDINAVICA, 1985, 56 (06) :469-473