Coil embolization of anterior circulation aneurysms supported by the Solitaire™ AB Neurovascular Remodeling Device

被引:37
作者
Klisch, Joachim [1 ]
Clajus, Christin [1 ]
Sychra, Vojtech [1 ]
Eger, Cornelia [1 ]
Strasilla, Christoph [1 ]
Rosahl, Steffen [2 ]
Gerlach, Ruediger [2 ]
Baer, Ingrid [3 ]
Hoch, Heinrich [4 ]
Herbon, Uta [5 ]
Borota, Ljubisa [6 ]
Jonasson, Per [6 ]
Liebig, Thomas [7 ]
机构
[1] HELIOS Gen Hosp Erfurt, Dept Diagnost & Intervent Radiol & Neuroradiol, D-99089 Erfurt, Germany
[2] HELIOS Gen Hosp Erfurt, Dept Neurosurg, D-99089 Erfurt, Germany
[3] Gen Hosp Nurnberg, Dept Diagnost & Intervent Radiol, Nurnberg, Germany
[4] HELIOS Gen Hosp Erfurt, Dept Neuroradiol, D-99089 Erfurt, Germany
[5] Gen Hosp Berlin Friedrichshain, Dept Diagnost & Intervent Radiol, Berlin, Germany
[6] Univ Hosp No Sweden, Neuroradiol Sect, Dept Radiol, Umea, Sweden
[7] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, D-8000 Munich, Germany
关键词
Anterior circulation aneurysms; Solitaire (TM) AB Neurovascular Remodeling Device; Coil embolization; NECKED INTRACRANIAL ANEURYSMS; SELF-EXPANDABLE STENT; GUGLIELMI DETACHABLE COILING; ENDOVASCULAR TREATMENT; EXPANDING STENT; CEREBRAL ANEURYSMS; NEUROFORM STENT; ENTERPRISE STENT; EXPERIENCE; PLACEMENT;
D O I
10.1007/s00234-009-0568-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of the study is to evaluate patients with wide-necked or complex aneurysms of the anterior circulation who underwent Solitaire (TM) AB Neurovascular Remodeling Device-assisted coil embolization. From February 2008 to March 2009, consecutive data were collected from 45 patients with anterior circulation aneurysms. Eighteen of the patients presented with acute subarachnoid hemorrhage. Forty-six aneurysms were treated with the aid of different applications (n = 49) of the Solitaire (TM) AB Remodeling Device followed by standard coiling procedure (n = 43) using bioactive coils or/and bare coils. Successful positioning of the remodeling device was obtained in 95.9% of the cases. There were two thromboembolic complications (4.1%) and one severe vasospasm requiring retrieval of the device. Permanent procedural morbidity was observed in one patient (2%). The proportion of patients in whom Raymond class 1 occlusion was obtained was 53.5% (n = 23). Raymond class 2 occlusion was achieved in 42% (n = 18) and Raymond class 3 occlusion in 4.7% (n = 2). Thirty-nine patients left the hospital with a good clinical status. The initial technical and clinical results of Solitaire (TM) AB device-assisted coiling of aneurysms in the anterior circulation are highly encouraging. This technique may enhance the possibilities of the endovascular treatment of these aneurysms in clinical routine.
引用
收藏
页码:349 / 359
页数:11
相关论文
共 45 条
[21]   Tako-tsubo cardiomyopathy in aneurysmal subarachnoid hemorrhage: an underappreciated ventricular dysfunction [J].
Lee, Vivien H. ;
Connolly, Heidi M. ;
Fulgham, Jimmy R. ;
Manno, Edward M. ;
Brown, Robert D., Jr. ;
Wijdicks, Eelco F. M. .
JOURNAL OF NEUROSURGERY, 2006, 105 (02) :264-270
[22]   Stent-assisted coil embolization of intracranial wide-necked aneurysms [J].
Lee, YJ ;
Kim, DJ ;
Suh, SH ;
Lee, SK ;
Kim, J ;
Kim, DI .
NEURORADIOLOGY, 2005, 47 (09) :680-689
[23]   Balloon-assisted Guglielmi detachable coiling of wide-necked aneurysms:: Part II -: Clinical results [J].
Lefkowitz, MA ;
Gobin, YP ;
Akiba, Y ;
Duckwiler, GR ;
Murayama, Y ;
Guglielmi, G ;
Martin, NA ;
Viñuela, F .
NEUROSURGERY, 1999, 45 (03) :531-537
[24]   A novel self-expanding fully retrievable intracranial stent (SOLO):: experience in nine procedures of stent-assisted aneurysm coil occlusion [J].
Liebig, T ;
Henkes, H ;
Reinartz, J ;
Miloslavski, E ;
Kühne, D .
NEURORADIOLOGY, 2006, 48 (07) :471-478
[25]   Retractable self-expandable stent for endovasculartreatment of wide-necked intracranial aneurysms:: Preliminary experience [J].
Lubicz, B ;
Leclerc, X ;
Levivier, M ;
Brotchi, J ;
Pruvo, JP ;
Lejeune, JP ;
Balériaux, D .
NEUROSURGERY, 2006, 58 (03) :451-456
[26]   Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents [J].
Lubicz, Boris ;
Collignon, Laurent ;
Lefranc, Florence ;
Bruneau, Michaeel ;
Brotchi, Jacques ;
Baleriaux, Danielle ;
De Witte, Olivier .
NEURORADIOLOGY, 2008, 50 (06) :499-507
[27]   Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms [J].
Lubicz, Boris ;
Bandeira, Alexandra ;
Bruneau, Michael ;
Dewindt, Aloys ;
Baleriaux, Danielle ;
De Witte, Olivier .
NEURORADIOLOGY, 2009, 51 (06) :419-425
[28]   Buenos aires experience with the neuroform self-expanding stent for the treatment of intracranial aneurysms [J].
Lylyk, P ;
Ferrario, A ;
Pabón, B ;
Miranda, C ;
Doroszuk, G .
JOURNAL OF NEUROSURGERY, 2005, 102 (02) :235-241
[29]  
Lylyk P, 2002, J ENDOVASC THER, V9, P160, DOI 10.1583/1545-1550(2002)009<0160:PCIAOW>2.0.CO
[30]  
2