Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning

被引:310
作者
Giraud, P
Antoine, M
Larrouy, A
Milleron, B
Callard, P
De Rycke, Y
Carette, MF
Rosenwald, JC
Cosset, JM
Housset, M
Touboul, E
机构
[1] Hop Tenon, Dept Radiat Oncol, F-75970 Paris, France
[2] Hop Tenon, Dept Pathol, F-75970 Paris, France
[3] Hop Tenon, Dept Pulm, F-75970 Paris, France
[4] Hop Tenon, Dept Radiol, F-75970 Paris, France
[5] Inst Curie, Dept Radiat Oncol, Paris, France
[6] Inst Curie, Dept Biostat, Paris, France
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 04期
关键词
three-dimensional conformal radiotherapy; computed tomography; histology; lung cancer;
D O I
10.1016/S0360-3016(00)00750-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: One of the most difficult steps of the three-dimensional conformal radiotherapy (3DCRT) is to define the clinical target volume (CTV) according to the degree of local microscopic extension (ME). In this study, we tried to quantify this ME in non-small-cell lung cancer (NSCLC), Material and Methods: Seventy NSCLC surgical resection specimens for which the border between tumor and adjacent lung parenchyma were examined on routine sections. This border was identified with the naked eye, outlined with a marker pen, and the value of the local ME outside of this border was measured with an eyepiece micrometer, The pattern of histologic spread was also determined. Results: A total of 354 slides were examined, corresponding to 176 slides for adenocarcinoma (ADC) and 178 slides for squamous cell carcinoma (SCC), The mean value of ME was 2.69 mm for ADC and 1.48 mm for SCC (p = 0,01), The usual 5-mm margin covers 80% of the ME for ADC and 91% for SCC. To take into account 95% of the R-IE, a margin of 8 mm and 6 mm must be chosen for ADC and SCC, respectively. Aerogenous dissemination was the most frequent pattern observed for all groups, followed by lymphatic invasion for ADC and interstitial extension for SCC. Conclusion: The ME was different between ADC and SCC, The usual CTV margin of 5 mm appears inadequate to cover the ME for either group, and it must be increased to 8 mm and 6 mm for I-IDC and SCC, respectively, to cover 95% of the ME. This approach is obviously integrated into the overall 3DCRT procedure and with other margins. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1015 / 1024
页数:10
相关论文
共 42 条
[1]  
AALTONEN P, 1996, ACTA ONCOL, V10, P1
[2]   Dose-effect relationships for functional local injury after lung irradiation [J].
Abratt, RP .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (02) :175-176
[3]   Applications of PET in lung cancer [J].
Al-Sugair, A ;
Coleman, RE .
SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (04) :303-319
[4]  
[Anonymous], 1995, TUMORS LOWER RESP TR
[5]   Planning target volumes for radiotherapy: How much margin is needed? [J].
Antolak, JA ;
Rosen, II .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1165-1170
[6]   STRATEGY FOR DOSE-ESCALATION USING 3-DIMENSIONAL CONFORMAL RADIATION-THERAPY FOR LUNG-CANCER [J].
ARMSTRONG, JG ;
ZELEFSKY, MJ ;
LEIBEL, SA ;
BURNAM, C ;
HAN, C ;
HARRISON, LB ;
KUTCHER, GJ ;
FUKS, ZY .
ANNALS OF ONCOLOGY, 1995, 6 (07) :693-697
[7]   Target volume definition for three-dimensional conformal radiation therapy of lung cancer [J].
Armstrong, JG .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846) :587-594
[8]  
Broderick LS, 1997, SEMIN ONCOL, V24, P411
[9]  
Bryne M, 1998, ANTICANCER RES, V18, P4757
[10]  
Carbone DP, 1997, SEMIN ONCOL, V24, P388