Target volume definition for three-dimensional conformal radiation therapy of lung cancer

被引:56
作者
Armstrong, JG [1 ]
机构
[1] St Lukes Hosp, Dublin 6, Ireland
关键词
D O I
10.1259/bjr.71.846.9849380
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional conformal radiation therapy (3DCRT) is a mode of high precision radiotherapy which has the potential to improve the therapeutic ratio of radiation therapy for locally advanced non-small cell lung cancer. The preliminary clinical experience with 3DCRT has been promising and justifies further endeavour to refine its clinical application and ultimately test its role in randomized trials. There are several steps to be taken before 3DCRT evolves into an effective single modality for the treatment of lung cancer and before it is effectively integrated with chemotherapy. This article addresses core issues in the process of target volume definition for the application of 3DCRT technology to lung cancer. The International Commission on Radiation Units and Measurements Report no. 50 definitions of target volumes are used to identify the factors influencing target volumes in lung cancer. The rationale for applying 3DCRT to lung cancer is based on the frequency of failure to eradicate gross tumour with conventional approaches. It may therefore be appropriate to ignore subclinical or microscopic extensions when designing a clinical target volume, thereby restricting target volume size and allowing dose escalation. When the clinical target volume is expanded to a planning target volume, an optimized margin would result in homogeneous irradiation to the highest dose feasible within normal tissue constraints. To arrive at such optimized margins, multiple factors, including data acquisition, data transfer, patient movement, treatment reproducibility, and internal organ and target volume motion, must be considered. These factors may vary significantly depending on technology and techniques, and published quantitative analyses are no substitute for meticulous attention to detail and audit of performance.
引用
收藏
页码:587 / 594
页数:8
相关论文
共 24 条
  • [1] Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer
    Armstrong, J
    Raben, A
    Zelefsky, M
    Burt, M
    Leibel, S
    Burman, C
    Kutcher, G
    Harrison, L
    Hahn, C
    Ginsberg, R
    Rusch, V
    Kris, M
    Fuks, Z
    [J]. RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) : 17 - 22
  • [2] Armstrong J G, 1994, Chest Surg Clin N Am, V4, P29
  • [3] 3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER
    ARMSTRONG, JG
    BURMAN, C
    LEIBEL, S
    FONTENLA, D
    KUTCHER, G
    ZELEFSKY, M
    FUKS, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04): : 685 - 689
  • [4] EFFECT OF CHEMOTHERAPY ON LOCALLY ADVANCED NON-SMALL-CELL LUNG-CARCINOMA - A RANDOMIZED STUDY OF 353 PATIENTS
    ARRIAGADA, R
    LECHEVALIER, T
    QUOIX, E
    RUFFIE, P
    DECREMOUX, H
    DOUILLARD, JY
    TARAYRE, M
    PIGNON, JP
    LAPLANCHE, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (06): : 1183 - 1190
  • [5] BALL D, 1997, LUNG CANCER S4, V18, P31
  • [6] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [7] TRANSFER ERRORS OF PLANNING CT TO SIMULATOR - A POSSIBLE SOURCE OF SETUP INACCURACIES
    BEL, A
    BARTELINK, H
    VIJLBRIEF, RE
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 31 (02) : 176 - 180
  • [8] Impact of cradle immobilization on setup reproducibility during external beam radiation therapy for lung cancer
    Bentel, GC
    Marks, LB
    Krishnamurthy, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (03): : 527 - 531
  • [9] EKBERG L, 1995, RADIOTHER ONCOL S1, V37, pS19
  • [10] TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING
    ELGAYED, AAH
    BEL, A
    VIJLBRIEF, R
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 26 (02) : 162 - 171