High-sensitivity capillary gel electrophoretic analysis of DNA fragments on an electrophoresis microchip using electrokinetic injection with transient isotachophoretic preconcentration

被引:58
作者
Xu, ZQ
Hirokawa, T
Nishine, T
Arai, A
机构
[1] Hiroshima Univ, Grad Sch Engn, Dept Chem & Chem Engn, Higashihiroshima 7398527, Japan
[2] Shimadzu Co, Life Sci Lab, Analyt & Measuring Instruments Div, Nakakyo Ku, Kyoto 6048511, Japan
关键词
chip technology; injection methods; isotachophoresis; DNA;
D O I
10.1016/S0021-9673(03)00053-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The research adopted a single-channel microchip as the probe, and focused electrokinetic injection combined with transient isotachophoresis preconcentration technique on capillary electrophoresis microchip to improve the analytical sensitivity of DNA fragments. The channel length, channel width and channel depth of the used microchip were 40.5 min, and 110 and 50 mum, respectively. The separation was detected by CCD (charge-coupled device) (effective length=25 mm, 260 nm). A 1/100 diluted sample (0.2 mg/l of each DNA fragment) of commercially available stepladder DNA sample could be baseline separated in 120 s with S/N=2-5. Compared with conventional chip gel electrophoresis, the proposed method is ideally suited to improve the sensitivity of DNA analysis by chip electrophoresis. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 26 条
[1]  
Beckers JL, 2000, ELECTROPHORESIS, V21, P2747, DOI 10.1002/1522-2683(20000801)21:14<2747::AID-ELPS2747>3.0.CO
[2]  
2-Z
[3]   Automated instrumentation for comprehensive isotachophoresis-capillary zone electrophoresis [J].
Chen, SJ ;
Lee, ML .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :816-820
[4]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[5]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[6]   ON-COLUMN TRANSIENT AND COUPLED COLUMN ISOTACHOPHORETIC PRECONCENTRATION OF PROTEIN SAMPLES IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :3-12
[7]   SAMPLE SELF-STACKING IN ZONE ELECTROPHORESIS - THEORETICAL DESCRIPTION OF THE ZONE ELECTROPHORETIC SEPARATION OF MINOR COMPOUNDS IN THE PRESENCE OF BULK AMOUNTS OF A SAMPLE COMPONENT WITH HIGH MOBILITY AND LIKE CHARGE [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :47-57
[8]   SAMPLE SELF-STACKING AND SAMPLE STACKING IN ZONE ELECTROPHORESIS WITH MAJOR SAMPLE COMPONENTS OF LIKE CHARGE - GENERAL-MODEL AND SCHEME OF POSSIBLE MODES [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
ELECTROPHORESIS, 1995, 16 (11) :2039-2050
[9]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[10]  
Hirokawa T, 2001, ELECTROPHORESIS, V22, P3483, DOI 10.1002/1522-2683(200109)22:16<3483::AID-ELPS3483>3.0.CO