Cine CT for attenuation correction in cardiac PET/CT

被引:79
作者
Alessio, Adam M.
Kohmyer, Steve
Branch, Kelley
Chen, Grace
Caldwell, James
Kinahan, Paul
机构
[1] Univ Washington, Old Fisheries Ctr, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[3] GE Healthcare, Waukesha, WA USA
关键词
PET/CT; 4DCT; attenuation correction; cardiac imaging; respiratory motion;
D O I
10.2967/jnumed.106.035717
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the attenuation correction factors and artifacts in the attenuation-corrected PET image. To rectify this problem, we evaluated the use of cine CT, which acquires multiple low-dose CT images during a respiratory cycle. We evaluated the average and the intensity-maximum image of cine CT for cardiac PET attenuation correction. Methods: Cine CT data and cardiac PET data were acquired from a cardiac phantom and from multiple patient studies. The conventional helical CT, cine CT, and PET data of an axially translating phantom were evaluated with and without respiratory motion. For the patient studies, we acquired 2 cine CT studies for each PET acquisition in a rest-stress N-13-ammonia protocol. Three readers visually evaluated the alignment of 74 attenuation image sets versus the corresponding emission image and determined whether the alignment provided acceptable or unacceptable attenuation-corrected PET images. Results: In the phantom study, the attenuation correction from helical CT caused a major artifactual defect in the lateral wall on the PET image. The attenuation correction from the average and from the intensity-maximum cine CT images reduced the defect by 20% and 60%, respectively. In the patient studies, 77% of the cases using the average of the cine CT images had acceptable alignment and 88% of the cases using the intensity maximum of the cine CT images had acceptable alignment. Conclusion: Cine CT offers an alternative to helical CT for compensating for respiratory motion in the attenuation correction of cardiac PET studies. Phantom studies suggest that the average and the intensity maximum of the cine CT images can reduce potential respiration-induced misalignment errors in attenuation correction. Patient studies reveal that cine CT provides acceptable alignment in most cases and suggest that the intensity-maximum cine image offers a more robust alternative to the average cine image.
引用
收藏
页码:794 / 801
页数:8
相关论文
共 28 条
[1]   PET myocardial glucose metabolism and perfusion imaging: Part I - Guidelines for patient preparation and data acquisition [J].
Bacharach, SL ;
Bax, JJ ;
Case, J ;
Delbeke, D ;
Kurdziel, KA ;
Martin, WH ;
Patterson, RE .
JOURNAL OF NUCLEAR CARDIOLOGY, 2003, 10 (05) :545-556
[2]   NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL FLOW RESERVE IN PATIENTS WITH CORONARY ATHEROSCLEROSIS USING N-13 AMMONIA POSITRON EMISSION TOMOGRAPHY - DETERMINATION OF EXTENT OF ALTERED VASCULAR REACTIVITY [J].
BEANLANDS, RSB ;
MUZIK, O ;
MELON, P ;
SUTOR, R ;
SAWADA, S ;
MULLER, D ;
BONDIE, D ;
HUTCHINS, GD ;
SCHWAIGER, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (06) :1465-1475
[3]   Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating [J].
Becker, CR ;
Knez, A ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :423-424
[4]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[5]   Non-invasive measurement of left ventricular volumes and function by gated positron emission tomography [J].
Boyd, HL ;
Gunn, RN ;
Marinho, NVS ;
Karwatowski, SP ;
Bailey, DL ;
Costa, DC ;
Camici, PG .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12) :1594-1602
[6]  
Chin Bennett B, 2003, Mol Imaging Biol, V5, P57, DOI 10.1016/S1536-1632(03)00044-1
[7]  
Cook R, 2005, IEEE NUCL SCI CONF R, P2408
[8]  
EINSTEIN AJ, 2006, J NUCL CARDIOL S, V13, pS15
[9]  
FITZPATRICK GM, 2003, IEEE NUCL SCI S C RE, V5, P3048
[10]   Respiration-induced attenuation artifact at PET/CT: Technical considerations [J].
Goerres, GW ;
Burger, C ;
Kamel, E ;
Seifert, B ;
Kaim, AH ;
Buck, A ;
Buehler, TC ;
von Schulthess, GK .
RADIOLOGY, 2003, 226 (03) :906-910