A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I

被引:219
作者
Choi, Dong Hwan [1 ]
Lee, Seok Ki [3 ]
Oh, Young Kyoung [1 ,2 ]
Bae, Byeong Woo [3 ]
Lee, Sung Dong [3 ]
Kim, Sanghyo [4 ]
Shin, Yong-Beom [1 ,2 ]
Kim, Min-Gon [1 ,2 ]
机构
[1] KRIBB, Biomonitoring Res Ctr, Taejon 305806, South Korea
[2] Univ Sci & Technol, Taejon 305333, South Korea
[3] Infopia Co Ltd, R&D Ctr, Anyang, Gyeonggi, South Korea
[4] Kyungwon Univ, Dept BioNanotechnol, Songnam 461701, Gyeonggi Do, South Korea
关键词
Lateral flow assay; Troponin I; Two gold nanoparticle conjugates;
D O I
10.1016/j.bios.2010.01.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
For signal amplification without an additional operation step in a gold nanoparticle (AuNP)-based lateral flow assay (LFA), a new and simple method utilizing two AuNP-antibody conjugates was developed. The 1st conjugate was the AuNP immobilized with an anti-troponin I antibody and blocked with bovine serum albumin (BSA), and the 2nd conjugate was the AuNP immobilized with an anti-BSA antibody and blocked with human serum albumin. The two conjugates were encapsulated in different pads, respectively. A scheme of the LFA system is described in the part A of first figure. The size of the two conjugates was very critical in the detection sensitivity of troponin I. When 10 nm for the 1st and 40 nm for the 2nd were used, the detection sensitivity increased about a 100-fold compared to the conventional LFA. We could detect as low as 0.01 ng/mL troponin I in 10 min using the dual AuNP conjugate-based LFA, which was successfully applied in the analysis of serum samples of patients with myocardial infarction. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1999 / 2002
页数:4
相关论文
共 9 条
  • [1] New frontiers in gold labeling
    Hainfeld, JF
    Powell, RD
    [J]. JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2000, 48 (04) : 471 - 480
  • [2] A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen
    Lin, Ying-Ying
    Wang, Jun
    Liu, Guodong
    Wu, Hong
    Wai, C. M.
    Lin, Yuehe
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) : 1659 - 1665
  • [3] Earlier detection of myocardial injury in a preliminary evaluation using a new troponin I assay with improved sensitivity
    Melanson, Stacy E. F.
    Morrow, David A.
    Jarolim, Petr
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (02) : 282 - 286
  • [4] Paek SH, 2007, BIOCHIP J, V1, P1
  • [5] Lateral flow (immuno) assay: its strengths, weaknesses, opportunities and threats. A literature survey
    Posthuma-Trumpie, Geertruida A.
    Korf, Jakob
    van Amerongen, Aart
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (02) : 569 - 582
  • [6] Colloidal gold-based immunochromatographic assay for detection of ricin
    Shyu, RH
    Shyu, HF
    Liu, HW
    Tang, SS
    [J]. TOXICON, 2002, 40 (03) : 255 - 258
  • [7] SOOD R., 2006, TXB MED LAB TECHNOLO, V1st
  • [8] USE OF 1.4-NM IMMUNOGOLD PARTICLES FOR IMMUNOCYTOCHEMISTRY ON ULTRA-THIN CRYOSECTIONS
    TAKIZAWA, T
    ROBINSON, JM
    [J]. JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1994, 42 (12) : 1615 - 1623
  • [9] A semi-quantitative dipstick assay for microcystin
    Tippkoetter, Nils
    Stueckmann, Henning
    Kroll, Stephen
    Winkelmann, Gunda
    Noack, Udo
    Scheper, Thomas
    Ulber, Roland
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (03) : 863 - 869