The Effect of Stent Porosity and Strut Shape on Saccular Aneurysm and its Numerical Analysis with Lattice Boltzmann Method

被引:76
作者
Kim, Yong Hyun [2 ]
Xu, Xiaofeng [2 ]
Lee, Joon Sang [1 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
[2] Wayne State Univ, Dept Mech Engn, Detroit, MI 48202 USA
关键词
Extrapolation method; Non-Newtonian flow; Hemodynamics; Secondary flow; BOUNDARY-CONDITIONS; BLOOD-FLOW; PULSATILE FLOWS; HEAT-TRANSFER; HEMODYNAMICS; PLACEMENT; STEADY; ARTERIAL; FRICTION; MODEL;
D O I
10.1007/s10439-010-9994-5
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The analysis of a flow pattern in cerebral aneurysms and the effect of stent strut shapes are presented in this article. The treatment of cerebral aneurisms with a porous stent has recently been proposed as a minimally invasive way to prevent rupture and favor coagulation mechanism inside the aneurism. The efficiency of stent is related to several parameters, including porosity and stent strut shapes. The goal of this article is to study the effect of the stent strut shape and porosity on the hemodynamic properties of the flow inside an aneurysm using a numerical analysis. In this study, we use the concept of flow reduction to characterize the stent efficiency. Also, we use the lattice Boltzmann method (LBM) of a non-Newtonian blood flow. To resolve the characteristics of a highly complex flow, we use an extrapolation method for the wall and stent boundary. To ease the code development and facilitate the incorporation of new physics, a scientific programming strategy based on object-oriented concepts is developed. Reduced velocity, smaller average vorticity magnitude, smaller average shear rate, and increased viscosity are observed when the proposed stent shapes and porosities are used. The rectangular stent is observed to be optimal and to decrease the magnitude of the velocity by 89.25% in the 2D model and 53.92% in the 3D model in the aneurysm sac. Our results show the role of the porosity and stent strut shape and help us to understand the characteristics of stent strut design.
引用
收藏
页码:2274 / 2292
页数:19
相关论文
共 54 条
[1]
Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[2]
The effects of roughness types on friction factors and heat transfer in roughened rectangular duct [J].
Ahn, SW .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2001, 28 (07) :933-942
[3]
BANDO K, 2003, COMP FLUID DYNAM J, V11, P527
[4]
Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics:: flow quantification in elastic sidewall aneurysm models [J].
Baráth, K ;
Cassot, F ;
Fasel, JHD ;
Ohta, M ;
Rüfenacht, DA .
NEUROLOGICAL RESEARCH, 2005, 27 :S120-S128
[5]
Burleson C., 1995, NEUROSURGERY, V37, P325
[6]
Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique [J].
Cebral, JR ;
Löhner, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :468-476
[7]
On boundary conditions in lattice Boltzmann methods [J].
Chen, SY ;
Martinez, D ;
Mei, RW .
PHYSICS OF FLUIDS, 1996, 8 (09) :2527-2536
[8]
CHO YI, 1991, BIORHEOLOGY, V28, P241
[9]
A KNUDSEN LAYER THEORY FOR LATTICE GASES [J].
CORNUBERT, R ;
DHUMIERES, D ;
LEVERMORE, D .
PHYSICA D, 1991, 47 (1-2) :241-259
[10]
Finol Ender A, 2002, Comput Methods Biomech Biomed Engin, V5, P319, DOI 10.1080/1025584021000009751