Evaluation of automated nucleic acid extraction devices for application in HCVNAT

被引:14
作者
Jongerius, JM
Bovenhorst, M
van der Poel, CL
van Hilten, JA
Kroes, ACM
van der Does, JA
van Leeuwen, EF
Schuurman, R
机构
[1] Bloedbank Midden Nederland, NL-3584 EA Utrecht, Netherlands
[2] Univ Utrecht Hosp, Utrecht, Netherlands
[3] Blood Bank Leiden Haaglanden, The Hague, Netherlands
[4] Leiden Univ, Med Ctr, Leiden, Netherlands
关键词
D O I
10.1046/j.1537-2995.2000.40070871.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To further improve the safety of the blood supply, various national blood transfusion organizations presently use or are in the process of implementing routine HCV NAT in minipools. According to the Committee for Proprietary Medicinal Products (CPMP) of the European Union, the HCV NAT detection limit of the assay should be 100 IU per mt (270 geq/mL) for testing initial plasma pools. Paul Ehrlich Institute (PEI) regulations stipulate that 5000 IU per mL (13,500 geq/mL) must be detected to calculate the amount contributed by individual donations composing the minipool. The sensitivity for HCV RNA extraction achieved by three commercially available laboratory kits was compared. STUDY DESIGN AND METHODS: Nucleic acids from 1-in-3 serial dilutions of an HCV RNA run control (Pelispy, CLB) were extracted with three kits (Cobas Amplicor, Roche Diagnostic Systems; BioRobot 9604, Qiagen; and NucliSens Extractor, Organon Teknika). HCV PCR of all extracts was performed using a second-generation Cobas Amplicor HCV test and the Cobas Amplicor analyzer. RESULTS: The manual Cobas Amplicor, the BioRobot 9604, and the NucliSens Extractor setups allow a 95-percent HCV RNA detection limit of 129, 82, and 12 geq per mt, respectively. The maximal pool size for the manual Cobas Amplicor, the BioRobot 9604, and the NucliSens Extractor kits that would still meet the PEI criteria for HCV NAT in minipools was calculated at 104, 164, and 1125 donations, respectively. CONCLUSION: All three HCV NAT kits evaluated meet the criteria set by CPMP and PEI. The highest sensitivity for HCV NAT screening can be achieved with the high-volume NucliSens Extractor method in combination with the Cobas Amplicor HCV v2.0 test on the Cobas Amplicor analyzer.
引用
收藏
页码:871 / 874
页数:4
相关论文
共 11 条
  • [1] RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS
    BOOM, R
    SOL, CJA
    SALIMANS, MMM
    JANSEN, CL
    WERTHEIMVANDILLEN, PME
    VANDERNOORDAA, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) : 495 - 503
  • [2] Mini-pool screening by nucleic acid testing for hepatitis B virus, hepatitis C virus, and HIV: preliminary results
    Cardoso, MS
    Koerner, K
    Kubanek, B
    [J]. TRANSFUSION, 1998, 38 (10) : 905 - 907
  • [3] International collaborative study on the second EUROHEP HCV-RNA reference panel
    Damen, M
    Cuypers, HTM
    Zaaijer, HL
    Reesink, HW
    Schaasberg, WP
    Gerlich, WH
    Niesters, HGM
    Lelie, PN
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1996, 58 (1-2) : 175 - 185
  • [4] Finney D.J., 1977, PROBIT ANAL, VIII
  • [5] Flanagan P, 1998, TRANSFUSION MED, V8, P9
  • [6] Screening blood donations for viral genomes:: multicenter study of real-time simulation using pooled samples on the model of hepatitis C virus RNA detection
    Lefrère, JJ
    Coste, J
    Defer, C
    Mercier, B
    Férec, C
    Loiseau, P
    Portelette, E
    Mariotti, M
    Lerable, J
    Rouger, P
    Pawlotsky, JM
    [J]. TRANSFUSION, 1998, 38 (10) : 915 - 923
  • [7] Lelie PN, 1998, INFUSIONSTHERAPIE, V25, P102
  • [8] Feasibility and efficacy of routine PCR screening of blood donations for hepatitis C virus, hepatitis B virus, and HIV-1 in a blood-bank setting
    Roth, WK
    Weber, M
    Seifried, E
    [J]. LANCET, 1999, 353 (9150) : 359 - 363
  • [9] The use of polymerase chain reaction in plasma pools for the concomitant detection of hepatitis C virus and HIV type 1 RNA
    Yerly, S
    Pedrocchi, M
    Perrin, L
    [J]. TRANSFUSION, 1998, 38 (10) : 908 - 914
  • [10] DETECTION OF HEPATITIS-C VIRUS-RNA BY A COMBINED REVERSE TRANSCRIPTION POLYMERASE CHAIN-REACTION ASSAY
    YOUNG, KKY
    RESNICK, RM
    MYERS, TW
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (04) : 882 - 886