Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure

被引:95
作者
Albert, NM
Hail, MD
Li, JB
Young, JB
机构
[1] Cleveland Clin Fdn, Div Nursing, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, George M & Linda H Kaufman Ctr Heart Failure, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
[4] Cleveland Clin Fdn, Dept Cardiovasc Med, Cleveland, OH 44195 USA
关键词
D O I
10.4037/ajcc2004.13.6.469
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND An accurate and reliable noninvasive method for determining cardiac output/cardiac index would be valuable for patients with acutely decompensated advanced systolic heart failure. OBJECTIVES To determine whether a correlation exists for cardiac output and index determined by using bioimpedance and thermodilution in patients with. acutely decompensated complex heart failure and if differences between results with the 2 methods could be explained by the patients' advanced condition. METHODS Cardiac output and index were determined by using bioimpedance and thermodilution in 33 patients. Echocardiographic and electrocardiographic data were assessed to determine if differences between results with the 2 methods could be explained by the patients' advanced condition. Concordance correlation coefficients and Bland-Altman agreement between methods were calculated. RESULTS Four patients were excluded from analysis because reliable measurements could not be obtained; the remaining 29 patients constituted the study population. Mean cardiac outputs determined by thermodilution and bioimpedance were 5.48 and 5.40 L/min, respectively (rho(c) =0.89, P < .001), and mean cardiac indexes were 2.67 and 2.65 (rho(c) = 0.82, P < .001). Mean bias (limits of agreement) between data pairs was 0.08 (-0.18 to 0.35) L/min (P = .52) for cardiac output and 0.03 (-0.097 to 0.16; P = .61) for cardiac index. Six data pairs (21%) had an absolute percent difference greater than 75%. Of these, 50% had a higher thermodilution value. CONCLUSION Determinations of cardiac output and index by both methods were significantly correlated. Mean bias between the 2 methods was small, suggesting clinical utility for bioimpedance in patients with complex decompensated heart, failure.
引用
收藏
页码:469 / 479
页数:11
相关论文
共 25 条
[1]  
AHMAD F, 1999, J CARD FAIL, V5, P81
[2]  
Albert N M, 1999, Am J Crit Care, V8, P464
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Severity of illness and risk of death associated with pulmonary artery catheter use [J].
Chittock, DR ;
Dhingra, VK ;
Ronco, JJ ;
Russell, JA ;
Forrest, DM ;
Tweeddale, M ;
Fenwick, JC .
CRITICAL CARE MEDICINE, 2004, 32 (04) :911-915
[5]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[6]   Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy [J].
Drazner, MH ;
Thompson, B ;
Rosenberg, PB ;
Kaiser, PA ;
Boehrer, JD ;
Baldwin, BJ ;
Dries, DL ;
Yancy, CW .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (08) :993-+
[7]  
Greenberg B H, 2000, Congest Heart Fail, V6, P74, DOI 10.1111/j.1527-5299.2000.80140.x
[8]  
Groom L, 1990, Crit Care Nurse, V10, P112
[9]  
Hendrickson K, 1999, AACN Clin Issues, V10, P419, DOI 10.1097/00044067-199908000-00012
[10]  
KALASSIAN KG, 1996, J CRIT ILLN, V11, P249