Femoral press-fit fixation of the hamstring tendons for anterior cruciate ligament reconstruction

被引:18
作者
Jagodzinski, M
Behfar, V
Hurschler, C
Albrecht, K
Krettet, C
Bosch, U
机构
[1] Hannover Med Sch, Dept Trauma Surg, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Orthoped Surg, Lab Biomech & Expt Orthoped, Hannover, Germany
[3] Hannover Med Sch, Dept Forens Med, Hannover, Germany
[4] INI, Ctr Orthoped & Sports Traumatol, Hannover, Germany
关键词
press-fit fixation; anterior cruxiate ligament (ACL); patella; hamstring;
D O I
10.1177/0363546503262692
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Press-fit fixation of patellar tendon-bone anterior cruciate ligament autografts is an interesting technique because no hardware is necessary. For hamstring tendon grafts, no biomechanical data exist of a press-fit procedure. Hypothesis: Press-fit femoral fixation of hamstring tendons is mechanically equivalent to press-fit patellar tendon-bone fixation. Study Design: Controlled laboratory study. Methods: Patellar and hamstring tendons of 30 human cadavers (age, 53.8 +/- 18.0 years) were used. An outside-in press-fit fixation with a knot in the semitendinosus and gracilis tendons and an inside-out and outside-in fixation with the tendons wrapped around a bone block were compared with patellar tendon-bone press-fit fixation in 30 ovine femora. Constructs were cyclically strained and then loaded until failure. Maximum load to failure, stiffness, and elongation during failure testing and cyclical loading were investigated. Results: The maximum load to failure was 561 +/- 309 N for the patellar tendon, 599 +/- 234 N for the semitendinosus/gracilis tendons knot construct, 678 +/- 231 for the semitendinosus/gracilis tendons bone construct inserted outside in, and 339 +/- 236 for the semitenclinosus/gracilis tendons bone construct inserted inside out (inferior to the others; analysis of variance, Dunn test, P < .01). Stiffness of the constructs averaged 134 +/- 32 N/mm for the patellar tendon, 124 +/- 21 N/mm for the knot construct, 118 +/- 27 N/mm for the outside-in fixation, and 117 +/- 23 N/mm for inside-out fixation. Elongation during initial cyclical loading was 0.7 +/- 0.6 mm for the patellar tendon, 1.6 +/- 0.5 mm for the knot construct, 1.9 +/- 1.2 mm for the outside-in fixation, and 1.9 +/- 0.9 mm for the inside-out fixation (significantly larger for all semitenclinosus/gracilis tendon techniques, P < .05). Conclusions: Failure loads for the semitendinosus/gracilis tendons bone construct inserted outside in and the semitendinosus/ gracilis tendons knot construct were within the confidence interval of the patellar tendon press-fit fixation. All semitenclinosus/gracilis tendon graft techniques exhibited larger elongation during initial cyclical loading than the patellar tendon graft. There was no difference in stiffness between all techniques. Clinical Relevance: Two of the 3 hamstring press-fit fixation techniques showed loads to failure similar to the patellar tendon fixation. Preconditioning of the constructs is critical. These results must be interpreted with care because of high standard deviations.
引用
收藏
页码:1723 / 1730
页数:8
相关论文
共 31 条
[1]
Adam F, 2001, ORTHOPADE, V30, P649, DOI 10.1007/s001320170053
[2]
Interference screw fixation of hamstring vs patellar tendon grafts for anterior cruciate ligament reconstruction [J].
Aune A.K. ;
Ekeland A. ;
Cawley P.W. .
Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (2) :99-102
[3]
Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws:: MR imaging follow-up [J].
Bach, FD ;
Carlier, RY ;
Elis, JB ;
Mompoint, DM ;
Feydy, A ;
Judet, O ;
Beaufils, P ;
Vallée, C .
RADIOLOGY, 2002, 225 (02) :541-550
[4]
Berg EE, 2001, ARTHROSCOPY, V17, P189, DOI 10.1053/jars.2001.20958
[5]
Arthroscopic anterior cruciate ligament reconstruction using a patellar tendon graft in press-fit technique: Surgical technique and follow-up [J].
Boszotta, H .
ARTHROSCOPY, 1997, 13 (03) :332-339
[6]
Tunnel widening in anterior cruciate ligament reconstruction: a prospective evaluation of hamstring and patella tendon grafts [J].
Clatworthy, MG ;
Annear, P ;
Bulow, JU ;
Bartlett, RJ .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (03) :138-145
[7]
Quadrupled semitendinosus anterior cruciate ligament reconstruction: 5-year results in patients without meniscus loss [J].
Cooley, VJ ;
Deffner, KT ;
Rosenberg, TD .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2001, 17 (08) :795-800
[8]
Fink C, 2001, ARTHROSCOPY, V17, P138, DOI 10.1053/jars.2001.21509
[9]
Arthroscopic anterior cruciate ligament reconstruction: A metaanalysis comparing patellar tendon and hamstring tendon autografts [J].
Freedman, KB ;
D'Amato, MJ ;
Nedeff, DD ;
Kaz, A ;
Bach, BR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (01) :2-11
[10]
FACTORS AFFECTING THE REGION OF MOST ISOMETRIC FEMORAL ATTACHMENTS .2. THE ANTERIOR CRUCIATE LIGAMENT [J].
HEFZY, MS ;
GROOD, ES ;
NOYES, FR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (02) :208-216