Hydrogen peroxide detection with improved selectivity and sensitivity using constant current potentiometry

被引:20
作者
Anh, DTV [1 ]
Olthuis, W [1 ]
Bergveld, P [1 ]
机构
[1] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
关键词
hydrogen peroxide sensor; constant current potentiometry; ascorbic acid;
D O I
10.1016/S0925-4005(03)00058-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a potentiometric H2O2 sensor based on a FET structure is presented. The sensor has a redox active gate contact such as Os-polyvinylpyridine (Os-PVP) containing the enzyme horseradish peroxidase (HRP) which has a high sensitivity to H2O2. The basic principle of the sensor is to measure hydrogen peroxide concentration by means of measuring the change in the work function of the electroactive gate of the FET due to its redox reaction with H2O2. A constant current potentiometric mode is used to improve the sensitivity of the sensor. To avoid the influence of ascorbic acid on the sensor, an additional layer of Nafion is mounted on top of the electroactive gate. The influence of the Nation concentration on the characteristics of the sensor (sensitivity and selectivity) has also been investigated. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 8 条
[1]   Electroactive Gate Materials for a Hydrogen Peroxide Sensitive EMOSFET [J].
Anh, Dam T. V. ;
Olthuis, W. ;
Bergveld, P. .
IEEE SENSORS JOURNAL, 2002, 2 (01) :26-33
[2]   Electrocatalytic reduction of hydrogen peroxide at platinum microparticles dispersed in a poly(o-phenylenediamine) film [J].
Cai, LT ;
Chen, HY .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (01) :14-18
[3]  
DANG DL, 2001, J ELECTROANAL CHEM, V501, P107
[4]   Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :85-92
[5]   The EMOSFET as an oxygen sensor:: constant current potentiometry [J].
Hendrikse, J ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 59 (01) :35-41
[6]   Selective permeation of hydrogen peroxide through polyelectrolyte multilayer films and its use for amperometric biosensors [J].
Hoshi, T ;
Saiki, H ;
Kuwazawa, S ;
Tsuchiya, C ;
Chen, Q ;
Anzai, J .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5310-5315
[7]   EFFECT OF INTERFERENCE ON THE PERFORMANCE OF GLUCOSE ENZYME ELECTRODES USING NAFION(R) COATINGS [J].
VAIDYA, R ;
ATANASOV, P ;
WILKINS, E .
MEDICAL ENGINEERING & PHYSICS, 1995, 17 (06) :416-424
[8]   HYDROGEN-PEROXIDE AND BETA-NICOTINAMIDE ADENINE-DINUCLEOTIDE SENSING AMPEROMETRIC ELECTRODES BASED ON ELECTRICAL CONNECTION OF HORSERADISH-PEROXIDASE REDOX CENTERS TO ELECTRODES THROUGH A 3-DIMENSIONAL ELECTRON RELAYING POLYMER NETWORK [J].
VREEKE, M ;
MAIDAN, R ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1992, 64 (24) :3084-3090