Analysis of minocycline by high-performance liquid chromatography in tissue and serum

被引:23
作者
Wrightson, WR
Myers, SR
Galandiuk, S [1 ]
机构
[1] Univ Louisville, Sch Med, Dept Surg, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Med, Dept Pharmacol, Louisville, KY 40292 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 706卷 / 02期
关键词
minocycline;
D O I
10.1016/S0378-4347(97)00647-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and rapid reversed-phase high-performance liquid chromatography assay can be used to accurately determine serum and tissue minocycline concentrations. Minocycline is a broad spectrum tetracycline derivative with many applications. Tissue and serum samples were obtained from guinea pigs that had received either topical or intravenous minocycline. Samples were extracted using a Sep-Pak C-18 cartridge and were injected into a mu Bondapak C-18 column with an isocratic methanol mobile phase. Samples were analyzed using UV detection and produced sharp peaks with a retention time of 2.5 min. The lower limit of detection was 100 ng and drug recovery was 61%. This method greatly facilitated the analysis of minocycline while allowing for sensitivity. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:358 / 361
页数:4
相关论文
共 7 条
[1]   DETERMINATION OF VANCOMYCIN IN SERUM AND TISSUES BY COLUMN LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION [J].
BAUCHET, J ;
PUSSARD, E ;
GARAUD, JJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (02) :472-476
[2]   CURRENT PERSPECTIVES ON ANTIBIOTIC USE IN THE TREATMENT OF SURGICAL INFECTIONS [J].
CHEADLE, WG .
AMERICAN JOURNAL OF SURGERY, 1992, 164 (4A) :S44-S47
[3]  
GALANDIUK S, 1989, SURG GYNECOL OBSTET, V169, P219
[4]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS OF TETRACYCLINE DERIVATIVES USING VOLATILE MOBILE PHASES [J].
HASAN, T ;
COOPERMAN, BS .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :462-466
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SYSTEM FOR ANALYSIS OF TETRACYCLINE DRUG STANDARDS, ANALOGS, DEGRADATION PRODUCTS AND OTHER IMPURITIES [J].
MACK, GD ;
ASHWORTH, RB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1978, 16 (03) :93-101
[6]   A RANDOMIZED, DOUBLE-BLIND TRIAL OF SINGLE DOSE PIPERACILLIN VERSUS MULTIDOSE CEFOXITIN IN ALIMENTARY-TRACT OPERATIONS [J].
POLK, HC ;
TRACHTENBERG, L ;
GEORGE, CD .
AMERICAN JOURNAL OF SURGERY, 1986, 152 (05) :517-521
[7]   DETERMINATION OF TETRACYCLINES IN BOVINE AND PORCINE MUSCLE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION [J].
WALSH, JR ;
WALKER, LV ;
WEBBER, JJ .
JOURNAL OF CHROMATOGRAPHY, 1992, 596 (02) :211-216