Stethoscopes and otoscopes - a potential vector of infection?

被引:73
作者
Cohen, HA [1 ]
Amir, J [1 ]
Matalon, A [1 ]
Mayan, R [1 ]
Beni, S [1 ]
Barzilai, A [1 ]
机构
[1] Tel Aviv Univ, Sackler Sch Med, Dept Family Med, Pediat Ambulatory Ctr, IL-49100 Petah Tiqwa, Israel
关键词
community paediatric clinics; otoscopes; Staphylococcus aureus; stethoscopes; vector of infection;
D O I
10.1093/fampra/14.6.446
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives. We aimed to determine whether stethoscopes and otoscopes used in community paediatric clinics harboured pathogenic micro-organisms, and, if so, which measures could prevent this. Methods. Fifty-five stethoscopes belonging to paediatric physicians working in 12 community clinics were sampled for bacterial cultures by two methods: (i) direct impression of the diaphragm and bell section of each stethoscope for 5 seconds onto blood agar plates and a mannitol-salt-agar plate; (ii) swabbing the entire surface of the diaphragm of the stethoscope with a sterile cotton-tipped applicator. Forty-two otoscopes from the same physicians were sampled by rubbing the handles of the otoscopes with cotton-tipped swabs. The plates were incubated at 37 degrees C for 48 hours and examined for colony growth at 24 and 48 hours of incubation. Culture results were recorded as mean numbers of colony-forming units (CFUs). Eight additional stethoscope diaphragms were chosen at random at the participating clinics and cultured as described above. They were then wiped with alcohol swabs (isopropyl alcohol 70%), allowed to air dry for approximately 10 minutes and cultured a second time. Results. All the stethoscopes and 90% of the otoscope handles were colonized by microorganisms. Staphylococci were isolated from 85.4% of the stethoscopes and 83.3% of the otoscopes, with 54.5% and 45.2% respectively being S. Aureus. Methicillin-resistant S. aureus were found in four each of the stethoscopes (7.3%) and otoscopes (9.5%). Cleaning with alcohol reduced the colony count by an average of 96.3%. Conclusions. Fomites can harbour potentially pathogenic bacteria, and with the increasing trend for children with more complex medical problems to be managed in an ambulatory setting, often by physicians who also work in hospitals, there is a real risk of spreading potentially serious infections to such patients. Simple cleansing with alcohol effectively eliminates the bacterial contamination of the fomites, and should be encouraged.
引用
收藏
页码:446 / 449
页数:4
相关论文
共 9 条
  • [1] BAUER AW, 1966, AM J CLIN PATHOL, V45, P493
  • [2] STETHOSCOPES AS POSSIBLE VECTORS OF INFECTION BY STAPHYLOCOCCI
    BREATHNACH, AS
    JENKINS, DR
    PEDLER, SJ
    [J]. BRITISH MEDICAL JOURNAL, 1992, 305 (6868) : 1573 - 1574
  • [3] ANTIBIOTIC-TREATMENT OF EXPERIMENTAL ENDOCARDITIS DUE TO METHICILLIN-RESISTANT STAPHYLOCOCCUS-EPIDERMIDIS
    ENTENZA, JM
    FLUCKIGER, U
    GLAUSER, MP
    MOREILLON, P
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1994, 170 (01) : 100 - 109
  • [4] GERKEN A, 1972, LANCET, V1, P1214
  • [5] THE EFFICACY OF INFECTION SURVEILLANCE AND CONTROL PROGRAMS IN PREVENTING NOSOCOMIAL INFECTIONS IN UNITED-STATES HOSPITALS
    HALEY, RW
    CULVER, DH
    WHITE, JW
    MORGAN, WM
    EMORI, TG
    MUNN, VP
    HOOTON, TM
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1985, 121 (02) : 182 - 205
  • [7] STETHOSCOPES - A POTENTIAL VECTOR OF INFECTION
    JONES, JS
    HOERLE, D
    RIEKSE, R
    [J]. ANNALS OF EMERGENCY MEDICINE, 1995, 26 (03) : 296 - 299
  • [8] HAND WASHING IN PEDIATRIC AMBULATORY SETTINGS - AN INCONSISTENT PRACTICE
    LOHR, JA
    INGRAM, DL
    DUDLEY, SM
    LAWTON, EL
    DONOWITZ, LG
    [J]. AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1991, 145 (10): : 1198 - 1199
  • [9] Contaminated stethoscopes revisited
    Smith, MA
    Mathewson, JJ
    Ulert, IA
    Scerpella, EG
    Ericsson, CD
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (01) : 82 - 84