Optimum kinetic performance of open-tubular separations in microfluidic devices

被引:15
作者
Eghbali, Hamed [1 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel VIB, Dept Chem Engn, B-1050 Brussels, Belgium
关键词
open-tubular devices; microfluidics; lab-on-a-chip;
D O I
10.1002/jssc.200600464
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A survey is made of the different factors contributing to the kinetic performance of open-tubular separation channels. Being representative for most of the channels used in microfluidic devices, the main focus is on channels with a rectangular format. Kinetic plots of t(0)/N-2 versus N are established to allow for a visual selection of the ideal channel format and dimensions. These plots for example show that in the pressure-driven mode a channel with a flat-rectangular crosssection (top and bottom wall covered by a retentive layer) can always yield slightly faster (some 15%) separations than a cylindrical capillary, provided the channel depth is optimized. If the channel depth is fixed, the optimal w/d-ratio depends on the required plate number. In electrically driven flows, the situation is reversed and rectangular channels with a small width are to be preferred, and the cylindrical capillary format becomes the best format.
引用
收藏
页码:1377 / 1397
页数:21
相关论文
共 48 条
[1]   ON THE DISPERSION OF A SOLUTE BY DIFFUSION, CONVECTION AND EXCHANGE BETWEEN PHASES [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1959, 252 (1271) :538-550
[2]   ON THE DISPERSION OF A SOLUTE IN A FLUID FLOWING THROUGH A TUBE [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1200) :67-77
[3]   Theory of capillary electrochromatograpy [J].
Bartle, KD ;
Myers, P .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :3-23
[4]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[5]  
Cengel YA, 2003, Heat transfer: A practical approach
[6]   An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases [J].
Ceriotti, L ;
de Rooij, NF ;
Verpoorte, E .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :639-647
[7]   RECTANGULAR CAPILLARY ELECTROPHORESIS - SOME THEORETICAL CONSIDERATIONS [J].
CIFUENTES, A ;
POPPE, H .
CHROMATOGRAPHIA, 1994, 39 (7-8) :391-404
[8]   Shear-driven flow approaches to LC and macromolecular separations [J].
Clicq, D ;
Pappaert, K ;
Vankrunkelsven, S ;
Vervoort, N ;
Baron, GV ;
Desmet, G .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :430A-438A
[9]  
Clicq D, 2004, LC GC EUR, V17, P278
[10]   Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology [J].
Desmet, G ;
Clicq, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4058-4070