Detection and noninvasive diagnostics of breast cancer with two-color laser optoacoustic imaging system

被引:16
作者
Ermilov, Sergey [1 ]
Stein, Alan [2 ]
Conjusteau, Andre [1 ]
Gharieb, Reda [1 ]
Lacewell, Ron [1 ]
Miller, Tom [1 ]
Thompson, Scott [2 ]
Otto, Pamela [3 ]
McCorvey, Barbara [3 ]
Khamapirad, Tuenchit [4 ]
Leonard, Morton [4 ]
Oraevsky, Alexander [1 ]
机构
[1] Fiarway Med Technol, 9431 W Sam Houston Pkwy S, Houston, TX 77099 USA
[2] Seno Med Instruments, San Antonio, TX 78229 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Canc Therapy & Res Ctr, San Antonio, TX 78229 USA
[4] Univ Texas Med Branch Galveston, Dept Radiol, Galveston, TX 77555 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007 | 2007年 / 6437卷
关键词
breast cancer; optoacoustic tomography; optoacoustic transducer array; image reconstruction; quantitative optoacoustic imaging;
D O I
10.1117/12.714039
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We have designed, fabricated and tested a new laser optoacoustic imaging system (LOIS-64/16) for quantitative optoacoustic tomography of breast cancer. The system was designed to create a single slice of an optoacoustic image of the breast with 64 ultrawide band acoustic transducers. Other 16 transducers on the back of the acoustic probe were used to reconstruct the light distribution inside the breast. The system resolution was at least 0.5 mm. for high-aspect-ratio objects. Maximum system sensitivity was 4.8 mV/Pa and the RMS noise of 3.1 mV, which allowed imaging of small (less than 1 cm) tumors at depths over 3 cm. The directivity of the optoacoustic transducers used in LOIS-64/16 assured that the signal detection was better than 70% of the maximum for about 75% of the imaging slice and reduced quickly for signals coming from out of the imaging slice. Implemented signal processing allowed significant reduction of the low-frequency acoustic noise and localizing the small OA signals. The system was able to differentiate phantoms mimicking tumors and malformations visualized in clinics based on the contrast and morphology of their images obtained at 1064 nm and 757 nm.
引用
收藏
页数:11
相关论文
共 24 条
[1]   Opto-acoustic tomography of breast cancer with arc-array-transducer [J].
Andreev, VG ;
Karabutov, AA ;
Solomatin, SV ;
Savateeva, EV ;
Aleynikov, V ;
Zhulina, YV ;
Fleming, RD ;
Oraevsky, AA .
BIOMEDICAL OPTOACOUSTICS, 2000, 3916 :36-47
[2]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[3]  
DIEBOLD GJ, 1994, ACUSTICA, V80, P339
[4]   PHOTOACOUSTIC SIGNATURES OF PARTICULATE MATTER - OPTICAL PRODUCTION OF ACOUSTIC MONOPOLE RADIATION [J].
DIEBOLD, GJ ;
KHAN, MI ;
PARK, SM .
SCIENCE, 1990, 250 (4977) :101-104
[5]   Screening for breast cancer [J].
Elmore, JG ;
Armstrong, K ;
Lehman, CD ;
Fletcher, SW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (10) :1245-1256
[6]  
ERMILOV A, 2006, P SOC PHOTO-OPT INS, V6086, P68
[7]   Measurement of optical transport properties of normal and malignant human breast tissue [J].
Ghosh, N ;
Mohanty, SK ;
Majumder, SK ;
Gupta, PK .
APPLIED OPTICS, 2001, 40 (01) :176-184
[8]   COMPREHENSIVE COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 (02) :423-457
[9]   Quantitative oximetry of breast tumors: a near-infrared method that identifies two optimal wavelengths for each tumor [J].
Heffer, EL ;
Fantini, S .
APPLIED OPTICS, 2002, 41 (19) :3827-3839
[10]   Temporal backward projection of optoacoustic pressure transients using Fourier transform methods [J].
Köstli, KP ;
Frenz, M ;
Bebie, H ;
Weber, HP .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :1863-1872