Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source

被引:81
作者
Baumbach, JI
Sielemann, S
Xie, ZY
Schmidt, H
机构
[1] ISAS, D-44139 Dortmund, Germany
[2] GAS Gesell Analyt Sensorsyst MBH, D-44227 Dortmund, Germany
关键词
D O I
10.1021/ac020342i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, ion mobility spectrometers (IMS) with radioactive and UV ionization sources in combination with multicapillary columns (MCCs) have been used to determine methyl tent-butyl ether (MTBE), a gasoline additive, in water and nitrogen as well as the monoaromatic compounds benzene, toluene, and m-xylene (BTX). A membrane extraction unit was set up to extract the substances from water, which is simple, effective, and easy to automate for further applications. Thus, the detection of MTBE and BTX of gasoline vapors was accomplished after a preliminary silicone membrane extraction. Two-dimensional data analyses of IMS-chromatograms allow us to separate these substances clearly according to their different retention and drift times. Method detection limits for MTBE were 2 mug/L (UV) and 30 pg/L (Ni-63) in nitrogen and 20 mg/L (UV) and 1mug/L (Ni-63) in water. Rather a good reproducibility was achieved with relative standard deviations of between 2.9 and 9%. The method presented in this article has been proven to be suitable for nearly real-time monitoring as the total analysis time is less than 90 s. As an example of application, the detection of MTBE and BTX in a mixture of volatile organic compounds of pure gasoline using the 2-D IMS-chromatogram is presented.
引用
收藏
页码:1483 / 1490
页数:8
相关论文
共 43 条
[1]  
ALEKSANDER J, 1976, J CHROMATOGR SCI, V14, P589
[2]  
[Anonymous], 1998, 510F97015 EPA, P1
[3]   SOLID-PHASE SAMPLE PREPARATION AND STABILITY OF PESTICIDES IN WATER USING EMPORE DISKS [J].
BARCELO, D ;
CHIRON, S ;
LACORTE, S ;
MARTINEZ, E ;
SALAU, JS ;
HENNION, MC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :352-361
[4]   Exploration of a multicapillary column for use in elevated speed gas chromatography [J].
Baumbach, JI ;
Eiceman, GA ;
Klockow, D ;
Sielemann, S ;
von Irmer, A .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1997, 66 (04) :225-239
[5]   Ion mobility spectrometry: Arriving on site and moving beyond a low profile [J].
Baumbach, JI ;
Eiceman, GA .
APPLIED SPECTROSCOPY, 1999, 53 (09) :338A-355A
[6]  
BAUMBACH JI, 1996, 5 INT WORKSH IMS JAC, P431
[7]   THE EXPERIMENTAL INVESTIGATION OF [C5H12O]+. ION STRUCTURES RELATED TO NEOPENTYL ALCOHOL AND ITS METHYL-ETHER [J].
BISSONNETTE, MC ;
GEORGE, M ;
HOLMES, JL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 101 (2-3) :309-324
[8]   USE OF A PERMEATION SAMPLER FOR DETERMINATION OF VOLATILE PRIORITY POLLUTANTS [J].
BLANCHARD, RD ;
HARDY, JK .
ANALYTICAL CHEMISTRY, 1984, 56 (09) :1621-1624
[9]  
*CAL PUBL HLTH GOA, 1999, PUBL HLTH GOAL METH
[10]   Trace analysis of ethanol, MTBE, and related oxygenate compounds in water using solid-phase microextraction and gas chromatography/mass spectrometry [J].
Cassada, DA ;
Zhang, Y ;
Snow, DD ;
Spalding, RF .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4654-4658