Extraction of the hepatic vasculature in rats using 3-D micro-CT images

被引:62
作者
Wan, SY [1 ]
Kiraly, AP
Ritman, EL
Higgins, WE
机构
[1] Penn State Univ, Dept Elect Engn CSE & Bioengn, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Comp Sci & Engn CSE, University Pk, PA 16802 USA
[3] Mayo Clin & Mayo Fdn, Dept Physiol & Biophys, Rochester, MN 55905 USA
关键词
angiography; hepatic imaging; liver; micro-CT imaging; region growing; small-animal imaging; three-dimensional image analysis; three-dimensional image processing; virtual endoscopy;
D O I
10.1109/42.887843
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
High-resolution micro-computed tomography (CT) scanners now exist for imaging small animals. In particular, such a scanner can generate very large three-dimensional (3-D) digital images of the rat's hepatic vasculature, These images provide data on the overall structure and function of such complex vascular trees. Unfortunately, human operators have extreme difficulty in extracting the extensive vasculature contained in the images. Also, no suitable tree representation exists that permits straightforward structural analysis and information retrieval. This work proposes an automatic procedure for extracting and representing such a vascular tree. The procedure is both computation and memory efficient and runs on current PCs. As the results demonstrate, the procedure faithfully follows human-defined measurements and provides far more information than can be defined interactively.
引用
收藏
页码:964 / 971
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 3 DIMENSIONAL BIOMED
[2]   In vivo diffusion-weighted magnetic resonance microscopy of rat spinal cord:: Effect of ischemia and intrathecal hyperbaric 5% lidocaine [J].
Benveniste, H ;
Qui, H ;
Hedlund, LW ;
Hüttemeier, PC ;
Steele, SM ;
Johnson, GA .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 1999, 24 (04) :311-318
[3]  
BENVENISTE H, 1999, HIGH RESOLUTION IMAG
[4]   Investigation of LSO crystals for high spatial resolution positron emission tomography [J].
Casey, ME ;
Eriksson, L ;
Schmand, M ;
Andreaco, MS ;
Paulus, M ;
Dahlbom, M ;
Nutt, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1109-1113
[5]   ADAPTIVE IMAGE REGION-GROWING [J].
CHANG, YL ;
LI, XB .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1994, 3 (06) :868-872
[6]   3-DIMENSIONAL X-RAY MICROTOMOGRAPHY [J].
FLANNERY, BP ;
DECKMAN, HW ;
ROBERGE, WG ;
DAMICO, KL .
SCIENCE, 1987, 237 (4821) :1439-1444
[7]   Three-dimensional microcomputed tomography of renal vasculature in rats [J].
Garcia-Sanz, A ;
Rodriguez-Barbero, A ;
Bentley, MD ;
Ritman, EL ;
Romero, JC .
HYPERTENSION, 1998, 31 (01) :440-444
[8]   IMAGE SEGMENTATION TECHNIQUES [J].
HARALICK, RM ;
SHAPIRO, LG .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1985, 29 (01) :100-132
[9]   System for analyzing high-resolution three-dimensional coronary angiograms [J].
Higgins, WE ;
Spyra, WJT ;
Karwoski, RA ;
Ritman, EL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :377-385
[10]  
Jain R., 1995, Machine Vision, V5