Extraction of the hepatic vasculature in rats using 3-D micro-CT images

被引:62
作者
Wan, SY [1 ]
Kiraly, AP
Ritman, EL
Higgins, WE
机构
[1] Penn State Univ, Dept Elect Engn CSE & Bioengn, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Comp Sci & Engn CSE, University Pk, PA 16802 USA
[3] Mayo Clin & Mayo Fdn, Dept Physiol & Biophys, Rochester, MN 55905 USA
关键词
angiography; hepatic imaging; liver; micro-CT imaging; region growing; small-animal imaging; three-dimensional image analysis; three-dimensional image processing; virtual endoscopy;
D O I
10.1109/42.887843
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
High-resolution micro-computed tomography (CT) scanners now exist for imaging small animals. In particular, such a scanner can generate very large three-dimensional (3-D) digital images of the rat's hepatic vasculature, These images provide data on the overall structure and function of such complex vascular trees. Unfortunately, human operators have extreme difficulty in extracting the extensive vasculature contained in the images. Also, no suitable tree representation exists that permits straightforward structural analysis and information retrieval. This work proposes an automatic procedure for extracting and representing such a vascular tree. The procedure is both computation and memory efficient and runs on current PCs. As the results demonstrate, the procedure faithfully follows human-defined measurements and provides far more information than can be defined interactively.
引用
收藏
页码:964 / 971
页数:8
相关论文
共 21 条
[11]   Feldkamp and circle-and-line cone-beam reconstruction for 3D micro-CT of vascular networks [J].
Johnson, RH ;
Hu, H ;
Haworth, ST ;
Cho, PS ;
Dawson, CA ;
Linehan, JH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :929-940
[12]  
JORGENSEN SM, 1998, AM J PHYSIOL, V275, P1103
[13]  
LUND PE, IN PRESS AM J PHYSL
[14]   3D DISPLAY OP HIGH-RESOLUTION VERTEBRAL STRUCTURE IMAGES [J].
PEYRIN, F ;
HOUSSARD, JP ;
MAURINCOMME, E ;
PEIX, G ;
GOUTTE, R ;
LAVALJEANTET, AM ;
AMIEL, M .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (4-5) :251-256
[15]   Synchrotron-based micro-CT of in situ biological basic functional units and their integration [J].
Ritman, EL ;
Jorgensen, SM ;
Lund, PE ;
Thomas, PJ ;
Dunsmuir, JH ;
Romero, JC ;
Turner, RT ;
Bolander, ME .
DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 :13-24
[16]   A new shape preserving parallel thinning algorithm for 3D digital images [J].
Saha, PK ;
Chaudhuri, BB ;
Dutta, D ;
Majumder, DD .
PATTERN RECOGNITION, 1997, 30 (12) :1939-1955
[17]  
SZEKELY G, 1994, P SOC PHOTO-OPT INS, V2359, P272
[18]   Heterogeneity of coronary arterial branching geometry [J].
Wan, SY ;
Reyes, DA ;
Higgins, WE ;
Ritman, EL .
MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 :515-520
[19]   Extraction and analysis of large vascular networks in 3D micro-CT images [J].
Wan, SY ;
Ritman, EL ;
Higgins, WE .
MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 :322-334
[20]  
WAN SY, 2000, IEEE INT C IM PROC I