Larger diameter bearings reduce wear in metal-on-metal hlp hnplants

被引:35
作者
Affatato, S.
Leardini, W.
Jedenmalm, A.
Ruggeri, O.
Toni, A.
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Royal Inst Technol, Dept Mat Sci & Engn, Stockholm, Sweden
[3] Inst Met, Fac Ind Chem, Bologna, Italy
[4] Ist Ortoped Rizzoli, Dept Orthopaed & Traumatol, I-40136 Bologna, Italy
关键词
D O I
10.1097/01.blo.0000246561.73338.68
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metal-on-metal hip arthroplasty has the longest clinical history of all total arthroplasties. We asked whether large diameter femoral heads would result in less wear than those with small diameters. We also asked if there is a threshold diameter that ensures good wear behavior. We tested three batches of cast high-carbon cobalt-chromium-molybdenum hip implants (28 mm, 36 min, and 54 min diameters) in a hip simulator for 5 million cycles. We used bovine serum as lubricant and weighed the samples at regular intervals during testing. The 28-mm configuration had almost twice the wear of the 54-mm configuration, but we observed no difference between the 36-mm and the 54-mm configurations. The similarity in the wear performances of the larger configurations supports the presence of a threshold diameter that ensures good wear behavior.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 54 条
[1]
Mixed-oxides prosthetic ceramic ball heads.: Part 2:: Effect of the ZrO2 fraction on the wear of ceramic on ceramic joints [J].
Affatato, S ;
Testoni, M ;
Cacciari, GL ;
Toni, A .
BIOMATERIALS, 1999, 20 (20) :1925-1929
[2]
Mixed oxides prosthetic ceramic ball heads.: Part 3:: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses.: A long-term in vitro wear study [J].
Affatato, S ;
Goldoni, M ;
Testoni, M ;
Toni, A .
BIOMATERIALS, 2001, 22 (07) :717-723
[3]
Total joint replacement of hip or knee as an outcome measure for structure modifying trials in osteoarthritis [J].
Altman, RD ;
Abadie, E ;
Avouac, B ;
Bouvenot, G ;
Branco, J ;
Bruyere, O ;
Calvo, G ;
Devogelaer, JP ;
Dreiser, RL ;
Herrero-Beaumont, G ;
Kahan, A ;
Kreutz, G ;
Laslop, A ;
Lemmel, EM ;
Menkes, CJ ;
Pavelka, K ;
Van De Putte, L ;
Vanhaelst, L ;
Reginster, JY .
OSTEOARTHRITIS AND CARTILAGE, 2005, 13 (01) :13-19
[4]
Amstutz H.C., 2001, WORLD TRIBOLOGY FORU, P113
[5]
Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
[6]
Amstutz HC, 1998, HIP INT, V8-4, P187
[7]
[Anonymous], 1424222000 ISO
[8]
[Anonymous], 2010, Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials, P1
[9]
*ASTM, 1996, ANN BOOK ASTM STAND, P1098
[10]
ASTM C, 1997, ANN BOOK ASTM STAND, P4