Stereotactic radiosurgery for lung tumors: Preliminary report of a phase I trial

被引:226
作者
Whyte, RI
Crownover, R
Murphy, MJ
Martin, DP
Rice, TW
DeCamp, MM
Rodebaugh, R
Weinhous, MS
Le, QT
机构
[1] Stanford Univ, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[4] Cleveland Clin Med Fdn, Dept Thorac Surg, Cleveland, OH USA
[5] Cleveland Clin Med Fdn, Dept Radiat Oncol, Cleveland, OH USA
关键词
D O I
10.1016/S0003-4975(02)04681-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Stereotactic radiosurgery is well established for the treatment of intracranial neoplasms but its use for lung tumors is novel. Methods. Twenty-three patients with biopsy-proven lung tumors were recruited into a two-institution, dose-escalation, phase I clinical trial using a frameless stereotactic radiosurgery system (CyberKnife). Fifteen patients had primary lung tumors and 8 had metastatic tumors. The age range was 23 to 87 years (mean, 63 years). After undergoing computed tomography-guided percutaneous placement of two to four small metal fiducials directly into the tumor, patients received 1,500 cGY of radiation in a single fraction using a linear accelerator mounted on a computer-controlled robotic arm. Safety, feasibility, and efficacy were studied. Results. Nine patients were treated with a breath-holding technique, and 14 with a respiratory-gating, automated, robotic technique. Tumor size ranged from I to 5 cm in maximal diameter. There were four complications related to fiducial placement: three pneumothoraces requiring chest tube insertion and one emphysema exacerbation. There were no grade 3 to 5 radiation-related complications. Follow-up ranged from I to 26 months (mean, 7.0 months). Radiographic response was scored as complete in 2 patients, partial in 15, stable in 4, and progressive in 2. Four patients died of non-treatment-related causes at 1, 5, 9, and 11 months after radiation. Conclusions. Single-fraction stereotactic radiosurgery is safe and feasible for the treatment of selected lung tumors. Additional studies are planned to investigate the optimal radiation dose, best motion-suppression technique, and overall treatment efficacy. (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:1097 / 1101
页数:5
相关论文
共 16 条
[1]   The cyberknife: A frameless robotic system for radiosurgery [J].
Adler, JR ;
Chang, SD ;
Murphy, MJ ;
Doty, J ;
Geis, P ;
Hancock, SL .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 69 (1-4) :124-128
[2]   A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER [J].
ANTONUK, LE ;
YORKSTON, J ;
HUANG, WD ;
SIEWERDSEN, JH ;
BOUDRY, JM ;
ELMOHRI, Y ;
MARX, MV .
RADIOGRAPHICS, 1995, 15 (04) :993-1000
[3]   STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS [J].
BLOMGREN, H ;
LAX, I ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1995, 34 (06) :861-870
[4]   Clinical experience with image-guided robotic radiosurgery (the Cyberknife) in the treatment of brain and spinal cord tumors [J].
Chang, SD ;
Murphy, M ;
Geis, P ;
Martin, DP ;
Hancock, SL ;
Doty, JR ;
Adler, JR .
NEUROLOGIA MEDICO-CHIRURGICA, 1998, 38 (11) :780-783
[5]   RANDOMIZED TRIAL OF LOBECTOMY VERSUS LIMITED RESECTION FOR T1 N0 NON-SMALL-CELL LUNG-CANCER [J].
HOLMES, CE ;
RUCKDESCHEL, JC ;
JOHNSTON, M ;
THOMAS, PA ;
DESLAURIERS, J ;
GROVER, FL ;
HILL, LD ;
FELD, R ;
GINSBERG, RJ ;
MOUNTAIN, CF ;
DZUIBAN, S ;
KIELY, M ;
MCKNEALLY, MF ;
MOORES, DWO ;
RAMNES, C ;
WAGNER, H ;
BUNN, P ;
CHU, H ;
DIENHART, D ;
HAZUKA, M ;
KINZIE, J ;
SORENSEN, J ;
VANCE, V ;
BRAUN, T ;
HOPEMAN, A ;
KANE, M ;
RUSS, P ;
WHITMAN, GJR ;
FALL, SM ;
HANSEN, DP ;
HENDERSON, RH ;
MONCRIEF, CL ;
PAULING, F ;
SIMS, J ;
TELL, D ;
WISELYCARR, S ;
ABERNATHY, CM ;
CLARK, DA ;
MCCROSKEY, B ;
MOORE, G ;
MOORE, F ;
MYERS, A ;
WHITE, M ;
BROOKS, RJ ;
BULL, M ;
JOHNSON, FB ;
NEIMYR, M ;
PAQUETTE, FR ;
SACCOMANNO, G ;
LAD, T .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :615-622
[6]  
KLAUS H, 1998, INT J RAD ONCOL B S1, V42, P214
[7]  
LEKSELL L, 1951, ACTA CHIR SCAND, V102, P316
[8]  
Schweikard A, 2000, Comput Aided Surg, V5, P263, DOI 10.1002/1097-0150(2000)5:4<263::AID-IGS5>3.0.CO
[9]  
2-2
[10]  
Takai Yoshihiro, 2001, Nippon Acta Radiologica, V61, P403