A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER

被引:64
作者
ANTONUK, LE [1 ]
YORKSTON, J [1 ]
HUANG, WD [1 ]
SIEWERDSEN, JH [1 ]
BOUDRY, JM [1 ]
ELMOHRI, Y [1 ]
MARX, MV [1 ]
机构
[1] UNIV MICHIGAN,MED CTR,DEPT RADIOL,ANN ARBOR,MI 48109
关键词
D O I
10.1148/radiographics.15.4.7569143
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As part of the development necessary for implementing a fully digital radiology department, the authors have investigated thin-film photodiodes and transistors for use in new photoelectronic imaging devices. One such device, a large-area, flat-panel, amorphous silicon imaging array, has been developed and is currently being tested. The array has a format of 512 x 560 pixels, a pixel-to-pixel pitch of 450 mu m, and an area of 230 x 252 mm(2), making it the largest self-scanning, solid-state imaging array developed to date. The array is used in conjunction with an overlying x-ray converter. Although specifically designed for megavoltage imaging, the device can produce high-quality, low spatial resolution, diagnostic x-ray images. Qualitative comparisons of array images of anthropomorphic head, chest, and pelvic phantoms and a spatial resolution pattern suggest that much of the information content of the film images at low spatial resolution is present in the corresponding array images. Current trends in the development of large-area, flat-panel imaging technology hold the promise of higher resolution arrays in the near future.
引用
收藏
页码:993 / 1000
页数:8
相关论文
共 25 条
  • [1] DIGITAL IMAGING IN RADIOLOGY - PRELIMINARY-RESULTS OBTAINED WITH A HIGH-SPATIAL-RESOLUTION 2D SILICON DETECTOR
    ALFANO, B
    BANDETTINI, A
    BENCIVELLI, W
    BERTOLUCCI, E
    BOTTIGLI, U
    CONTI, M
    DELGUERRA, A
    FANTACCI, ME
    GAMBACCINI, M
    LAROBINA, M
    MARZIANI, M
    RANDACCIO, P
    ROSSO, V
    RUSSO, P
    STEFANINI, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 987 - 991
  • [2] ALLEN B, 1994, P SOC PHOTO-OPT INS, V2163, P264, DOI 10.1117/12.174263
  • [3] ANTONUK LE, 1993, MATER RES SOC SYMP P, V297, P945, DOI 10.1557/PROC-297-945
  • [4] RADIATION RESPONSE OF AMORPHOUS-SILICON IMAGING ARRAYS AT DIAGNOSTIC ENERGIES
    ANTONUK, LE
    SIEWERDSEN, JH
    YORKSTON, J
    HUANG, W
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1500 - 1505
  • [5] DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    MCSHAN, DL
    MORTON, EJ
    YORKSTON, J
    LONGO, MJ
    STREET, RA
    [J]. MEDICAL PHYSICS, 1992, 19 (06) : 1455 - 1466
  • [6] DEVELOPMENT OF HYDROGENATED AMORPHOUS-SILICON SENSORS FOR DIAGNOSTIC-X-RAY IMAGING
    ANTONUK, LE
    KIM, CW
    BOUDRY, J
    YORKSTON, J
    LONGO, MJ
    STREET, RA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 636 - 640
  • [7] ANTONUK LE, 1994, MATER RES SOC SYMP P, V336, P855, DOI 10.1557/PROC-336-855
  • [8] THIN-FILM, FLAT-PANEL, COMPOSITE IMAGERS FOR PROJECTION AND TOMOGRAPHIC IMAGING
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    LAM, KL
    MORTON, EJ
    TENHAKEN, RK
    YORKSTON, J
    CLINTHORNE, NH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) : 482 - 490
  • [9] ANTONUK LE, 1992, P SOC PHOTO-OPT INS, V1651, P94, DOI 10.1117/12.59387
  • [10] ANTONUK LE, 1994, P SOC PHOTO-OPT INS, V2163, P118, DOI 10.1117/12.174247