Predicting out-of-office blood pressure level using repeated measurements in the clinic: an observational cohort study

被引:26
作者
Sheppard, James P. [1 ,2 ]
Holder, Roger [2 ,3 ]
Nichols, Linda [2 ,3 ]
Bray, Emma [4 ]
Hobbs, F. D. Richard [1 ,2 ]
Mant, Jonathan [5 ]
Little, Paul [2 ,6 ]
Williams, Bryan [7 ,8 ]
Greenfield, Sheila [2 ,3 ]
McManus, Richard J. [1 ,2 ]
机构
[1] Univ Oxford, Nuffield Dept Primary Care Hlth Sci, Oxford OX2 6GG, England
[2] Natl Inst Hlth Res, Sch Primary Care Res, Radcliffe Observ Quarter, Oxford, England
[3] Univ Birmingham, Birmingham, W Midlands, England
[4] Univ Cent Lancashire, Sch Psychol, Preston PR1 2HE, Lancs, England
[5] Univ Cambridge, Inst Publ Hlth, Primary Care Unit, Cambridge, England
[6] Univ Southampton, Sch Med, Southampton, Hants, England
[7] UCL, Inst Cardiovasc Sci, London, England
[8] UCL Hosp Biomed Res Ctr, Natl Inst Hlth Res, London, England
关键词
home-clinic blood pressure difference; hypertension; masked effect; sensitivity; specificity; white-coat effect; WHITE-COAT HYPERTENSION; MASKED HYPERTENSION; SYSTOLIC HYPERTENSION; AUTOMATED MEASUREMENT; GENERAL-POPULATION; CARDIAC STRUCTURE; PRIMARY-CARE; RISK; HOME; PREVALENCE;
D O I
10.1097/HJH.0000000000000319
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35-84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice.
引用
收藏
页码:2171 / 2178
页数:8
相关论文
共 41 条
[11]  
Lewington S, 2002, LANCET, V360, P1903, DOI 10.1016/S0140-6736(02)11911-8
[12]   Cardiac and arterial target organ damage in adults with elevated ambulatory and normal office blood pressure [J].
Liu, JE ;
Roman, MJ ;
Pini, R ;
Schwartz, JE ;
Pickering, TG ;
Devereux, RB .
ANNALS OF INTERNAL MEDICINE, 1999, 131 (08) :564-+
[13]   Cost-effectiveness of options for the diagnosis of high blood pressure in primary care: a modelling study [J].
Lovibond, Kate ;
Jowett, Sue ;
Barton, Pelham ;
Caulfield, Mark ;
Heneghan, Carl ;
Hobbs, F. D. Richard ;
Hodgkinson, James ;
Mant, Jonathan ;
Martin, Una ;
Williams, Bryan ;
Wonderling, David ;
McManus, Richard J. .
LANCET, 2011, 378 (9798) :1219-1230
[14]  
MacDonald MB, 1999, CAN MED ASSOC J, V161, P265
[15]   Long-term risk of mortality associated with selective and combined elevation in office, home, and ambulatory blood pressure [J].
Mancia, G ;
Facchetti, R ;
Bombelli, M ;
Grassi, G ;
Sega, R .
HYPERTENSION, 2006, 47 (05) :846-853
[16]  
Mancia G, 1997, CIRCULATION, V95, P1464
[17]  
Mancia G, 2007, EUR HEART J, V28, P1462, DOI [10.1093/eurheartj/ehm236, 10.1093/eurheartj/eht151]
[18]   Overall accuracy of the BpTRU™ -: an automated electronic blood pressure device [J].
Mattu, GS ;
Heran, BS ;
Wright, JM .
BLOOD PRESSURE MONITORING, 2004, 9 (01) :47-52
[19]   Comparison of the oscillometric blood pressure monitor (BIRM-100beta) with the auscultatory mercury sphygmomanometer [J].
Mattu, GS ;
Perry, TL ;
Wright, JM .
BLOOD PRESSURE MONITORING, 2001, 6 (03) :153-159
[20]   Telemonitoring and self-management in the control of hypertension (TASMINH2): a randomised controlled trial [J].
McManus, Richard ;
Mant, Jonathan ;
Bray, Emma P. ;
Holder, Roger ;
Jones, Miren I. ;
Greenfield, Sheila ;
Kaambwa, Billingsley ;
Banting, Miriam ;
Bryan, Stirling ;
Little, Paul ;
Williams, Bryan ;
Hobbs, F. D. Richard .
LANCET, 2010, 376 (9736) :163-172