Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws

被引:156
作者
Seebeck, J
Goldhahn, J
Städele, H
Messmer, P
Morlock, MM
Schneider, E
机构
[1] AO Res Inst, CH-7270 Davos, Switzerland
[2] Univ Hosp, CAR, CAS, Res Grp, Basel, Switzerland
[3] Tech Univ Hamburg, Biomech Sect, Hamburg, Germany
关键词
screw fixation; internal fixation; bone morphology; fracture treatment;
D O I
10.1016/j.orthres.2004.04.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Internal fixators are a new class of implants designed to preserve the periosteal blood supply of the bone. In contrast to conventional plate fixation in which the screws have spherical heads and are loaded mainly by axial pullout forces, screws in internal fixators are "locked" within the plate and therefore subjected to axial as well as bending loads. In this study the ultimate loads of screws of a commercially available internal fixator system were tested in a pullout (n = 72) and cantilever bending mode (n = 72) in metaphyseal and diaphyseal regions of four pairs of human tibiae with different bone qualities. Cortical thickness and cancellous bone density were determined at the screw insertion sites. Stepwise multiple linear regression revealed that cortical thickness and cancellous density can explain 93% and 98% of the variance of the ultimate load of the screws in an axial pullout and cantilever bending mode. Screws in internal fixators are better suited to transmit shear forces and thereby make better use of the strength potential of bone than screws used in conventional plate fixation: this is especially advantageous when bone strength is reduced, e.g. due to osteoporosis. (C) 2004 Published by Elsevier Ltd. on behalf of Orthopaedic Research Society.
引用
收藏
页码:1237 / 1242
页数:6
相关论文
共 26 条
[1]
Cancellous bone screw thread design and holding power [J].
Asnis, SE ;
Ernberg, JJ ;
Bostrom, MPG ;
Wright, TM ;
Harrington, RM ;
Tencer, A ;
Peterson, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (07) :462-469
[2]
Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws [J].
Brown, GA ;
McCarthy, T ;
Bourgeault, CA ;
Callahan, DJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (02) :307-312
[3]
Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[4]
EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[5]
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[6]
Age variations in the properties of human tibial trabecular bone [J].
Ding, M ;
Dalstra, M ;
Danielsen, CC ;
Kabel, J ;
Hvid, I ;
Linde, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06) :995-1002
[7]
Effect of bone quality on the forces generated by compression screws [J].
Faran, KJ ;
Ichioka, N ;
Trzeciak, MA ;
Han, S ;
Medige, J ;
Moy, OJ .
JOURNAL OF BIOMECHANICS, 1999, 32 (08) :861-864
[8]
The dependence of shear failure properties of trabecular bone on apparent density and trabecular orientation [J].
Ford, CM ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 1996, 29 (10) :1309-1317
[9]
Frigg R, 2001, Injury, V32 Suppl 2, P63, DOI 10.1016/S0020-1383(01)00127-9
[10]
Determination of the role of the cancellous bone in generation of screw holding power at metaphysis [J].
Harnroongroj, T ;
Techataweewan, A .
CLINICAL BIOMECHANICS, 1999, 14 (05) :364-366