The Initial Extent of Malapposition in ST-Elevation Myocardial Infarction Treated with Drug-Eluting Stent: The Usefulness of Optical Coherence Tomography

被引:20
作者
Kim, Ung [2 ]
Kim, Jung-Sun [1 ]
Kim, Jin-Sun [1 ]
Lee, Jung-Myung [1 ]
Son, Jung-Woo [1 ]
Kim, Jaedeok [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Yonsei Cardiovasc Ctr, Seoul 120752, South Korea
[2] Inje Univ, Coll Med, Div Cardiol, Pusan Paik Hosp, Pusan, South Korea
关键词
Malapposition; drug eluting stent; coherence tomography; optical; myocardial infarction; INTRAVASCULAR ULTRASOUND ANALYSIS; IMPLANTATION; THROMBOSIS; PREDICTORS;
D O I
10.3349/ymj.2010.51.3.332
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The aim of this study is to identify the extent of initial malapposition using optical coherence tomography (OCT) in ST-elevation myocardial infarctions (STEMI) treated with different types of drug-eluting stems (DES) Materials and Methods: Twenty four STEMI patients that underwent primary percutaneous coronary intervention (PCI) were enrolled The OCT and intravascular ultrasound ((IVUS) were performed within 72 hours after the primary PCI. Distances between the endo-luminal surface of the strut reflection and the vessel wall and the extent of malapposition were measured and analyzed. Results: Sirolimus-eluting stems (SES), paclitaxel-eluting stents (PES) and zotarolimus-eluting stents (ZES) were deployed in 7 patients (29%), 7 patients (29%) and 10 patients (42%). In total, 4951 struts in 620 mm single-stem segments were analyzed (1463 struts in SES, 1522 in PES, and 1966 in ZES) In strut analysis by OCT, the incidence of malapposition was 17 % (860/4951) and in stem analysis by IVUS, malapposition rate was 21% (5/24) The malapposition rate of strut level using OCT in 5 patients who had malapposition in IVUS was significantly higher than the 19 of those who had not (32 +/- 5% vs 12 +/- 6%, p = 0.001) In addition, the frequency of malapposition was also significantly different (28% in SES, 11% in PES, 10% in ZES, p = 0 001) The use of SES was an independent predictor of malapposed struts Conclusion: The incidence of malapposition using OCT was quite prevalent in STEMI after primary PCI with DES implantation and SES has especially higher rates of malapposition compared to other DESs
引用
收藏
页码:332 / 338
页数:7
相关论文
共 17 条
[1]   Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis [J].
Ako, J ;
Morino, Y ;
Honda, Y ;
Hassan, A ;
Sonoda, S ;
Yock, PG ;
Leon, MB ;
Moses, JW ;
Bonneau, HN ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) :1002-1005
[2]   Evaluation of intracoronary stenting by intravascular optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Yabushita, H ;
Shishkov, M ;
Kauffman, CR ;
Gauthier, DD ;
MacNeill, BD ;
Houser, SL ;
Aretz, HT ;
Halpern, EF ;
Jang, IK .
HEART, 2003, 89 (03) :317-320
[3]   Predictors of subacute stent thrombosis - Results of a systematic intravascular ultrasound study [J].
Cheneau, E ;
Leborgne, L ;
Mintz, GS ;
Kotani, J ;
Pichard, AD ;
Satler, LF ;
Canos, D ;
Castagna, M ;
Weissman, NJ ;
Waksman, R .
CIRCULATION, 2003, 108 (01) :43-47
[4]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[5]   Optical coherence tomography as a tool for percutaneous coronary interventions [J].
Diaz-Sandoval, LJ ;
Bourna, BE ;
Tearney, GJ ;
Jang, IK .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (04) :492-496
[6]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419
[7]   In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography [J].
Jang, IK ;
Tearney, GJ ;
MacNeill, B ;
Takano, M ;
Moselewski, F ;
Iftima, N ;
Shishkov, M ;
Houser, S ;
Aretz, HT ;
Halpern, EF ;
Bouma, BE .
CIRCULATION, 2005, 111 (12) :1551-1555
[8]   Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound [J].
Jang, IK ;
Bouma, BE ;
Kang, DH ;
Park, SJ ;
Park, SW ;
Seung, KB ;
Choi, KB ;
Shishkov, M ;
Schlendorf, K ;
Pomerantsev, E ;
Houser, SL ;
Aretz, HT ;
Tearney, GJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) :604-609
[9]   Assessment of coronary intima-media thickness by optical coherence tomography - Comparison with intravascular ultrasound [J].
Kume, T ;
Akasaka, T ;
Kawamoto, T ;
Watanabe, N ;
Toyota, E ;
Neishi, Y ;
Sukmawan, R ;
Sadahira, Y ;
Yoshida, K .
CIRCULATION JOURNAL, 2005, 69 (08) :903-907
[10]   Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: Intravascular ultrasound results from ENDEAVOR III [J].
Miyazawa, Akiyoshi ;
Ako, Junya ;
Hongo, Yoichiro ;
Hur, Seung-Ho ;
Tsujino, Ichizo ;
Courtney, Brian K. ;
Hassan, Ali H. M. ;
Kandzari, David E. ;
Honda, Yasuhiro ;
Fitzgerald, Peter J. .
AMERICAN HEART JOURNAL, 2008, 155 (01) :108-113