Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system

被引:78
作者
Combes, P
Fauvage, B
Oleyer, C
机构
[1] CHU Grenoble, F-38043 Grenoble 9, France
[2] Ctr Hosp Roanne, Dept Informat Med & Sante Publ, F-42300 Roanne, France
关键词
nosocomial pneumopathy; mechanical ventilation; Cox model; closed suctioning device; ICU;
D O I
10.1007/s001340051276
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the ventilator-associated pneumonia (VAP) incidence rates in mechanically ventilated patients according to the type of endotracheal suctioning (closed versus open). Setting: The Neurosurgery Intensive Care Unit of the Grenoble University Hospital, France. Design: A prospective randomised study performed after a 6-month period of nursing personnel training. Patients: One hundred four consecutive patients needing mechanical ventilation for more than 48 h were randomised into two groups. To be eligible, patients had to have no active infection or respiratory affection in their passes. In the Stericath group (S + n = 54), patients were not; disconnected from the ventilator during suctioning. The others were routinely managed (S-, n = 50). In both groups patterns of frequency and duration of suctioning were performed according to a standardised protocol. Measurements: The non-adjusted incidence rate of VAP was lower for S + than for S- (7.32 versus15.89 per 1000 patient-days, p = 0.07). Multivariate analysis performed using the Cox model showed an adjusted risk of VAP 3.5 times higher in S- (95 % Cl: 11.00-12.33). The risk being 4.3 higher in patients receiving gastric acid secretion inhibitors (1.08-16.82). In non-censored cases (n = 76) length of ICU stay increased by an average of 16.8 days when VAP was present (p = 0.0008). No adverse effect due to Stericath use was noted and volume of tracheal aspirate was similar between groups (p = 0.178). Conclusion: The use of Stericath reduced the incidence rate of VAP without demonstrating any adverse effect.
引用
收藏
页码:878 / 882
页数:5
相关论文
共 40 条
[31]   PNEUMONIA - INCIDENCE, RISK-FACTORS, AND OUTCOME IN INJURED PATIENTS [J].
RODRIGUEZ, JL ;
GIBBONS, KJ ;
BITZER, LG ;
DECHERT, RE ;
STEINBERG, SM ;
FLINT, LM .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1991, 31 (07) :907-914
[32]  
RUDY EB, 1991, HEART LUNG, V20, P667
[33]   Impact of invasive and noninvasive quantitative culture sampling on outcome of ventilator-associated pneumonia -: A pilot study [J].
Sanchez-Nieto, JM ;
Torres, A ;
Garcia-Cordoba, F ;
El-Ebiary, M ;
Carrillo, A ;
Ruiz, J ;
Nuñez, ML ;
Niederman, M .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (02) :371-376
[34]  
TEASDALE G, 1974, LANCET, V2, P81
[35]   Mortality of nosocomial pneumonia in ventilated patients: Influence of diagnostic tools [J].
Timsit, JF ;
Chevret, S ;
Valcke, J ;
Misset, B ;
Renaud, B ;
Goldstein, FW ;
Vaury, P ;
Carlet, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (01) :116-123
[36]  
TORRES A, 1990, AM REV RESPIR DIS, V142, P521
[37]   Randomized, controlled trial of selective digestive decontamination in 600 mechanically ventilated patients in a multidisciplinary intensive care unit [J].
Verwaest, C ;
Verhaegen, J ;
Ferdinande, P ;
Schetz, M ;
VandenBerghe, G ;
Verbist, L ;
Lauwers, P .
CRITICAL CARE MEDICINE, 1997, 25 (01) :63-71
[38]  
WEINSTEIN R, 1991, AM J MED S3B, V91, P180
[39]  
Wunderink RG, 1998, AM J RESP CRIT CARE, V157, P349
[40]  
WUNDERINK RG, 1992, CHEST, V102, P580