Comparison of five commercial serological tests for the detection of anti-Chlamydia trachomatis antibodies

被引:34
作者
Baud, D. [1 ,2 ]
Regan, L. [2 ]
Greub, G. [1 ]
机构
[1] Univ Lausanne, Fac Biol & Med, Inst Microbiol, Ctr Res Intracellular Bacteria, CH-1011 Lausanne, Switzerland
[2] Univ London Imperial Coll Sci Technol & Med, St Marys Hosp, Dept Obstet & Gynaecol, London, England
基金
瑞士国家科学基金会;
关键词
ATYPICAL BACTERIAL PNEUMONIA; PELVIC-INFLAMMATORY-DISEASE; HEAT-SHOCK-PROTEIN; PREGNANT-WOMEN; INFECTIONS; ASSAYS; IGG; SERODIAGNOSIS; IMMUNOASSAYS; SURVEILLANCE;
D O I
10.1007/s10096-010-0912-4
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Screening for Chlamydia trachomatis-specific antibodies is valuable in investigating recurrent miscarriage, tubal infertility and extrauterine pregnancy. We compared here the performance of immunofluorescence (IF) to four other commercial tests in detecting IgG antibodies directed against C. trachomatis: two enzyme-linked immunosorbent assays (ELISAs) using the major outer membrane protein (MOMP) as the antigen, commercialised respectively by Medac and R-Biopharm (RB), one ELISA using the chlamydial heat shock protein 60 (cHSP60) as the antigen (Medac), as well as a new automated epifluorescence immunoassay (InoDiag). A total of 405 patients with (n = 251) and without (n = 154) miscarriages were tested by all five tests. The prevalence of C. trachomatis-specific IgG antibodies as determined by the IF, cHSP60-Medac, MOMP-Medac, MOMP-RB and InoDiag was 14.3, 23.2, 14.3, 11.9 and 26.2%, respectively. InoDiag exhibited the highest sensitivity, whereas MOMP-RB showed the best specificity. Cross-reactivity was observed with C. pneumoniae using IF, MOMP-RB and InoDiag, and Parachlamydia acanthamoebae using the cHSP60 ELISA test. No cross-reactivity was observed between C. trachomatis and the other Chlamydiales (Neochlamydia hartmannellae, Waddlia chondrophila and Simkania negevensis). Given its high sensitivity, the new automated epifluorescence immunoassay from InoDiag represents an interesting alternative. The MOMP-based ELISA of R-Biopharm should be preferred for large serological studies, given the high throughput of ELISA and its excellent specificity.
引用
收藏
页码:669 / 675
页数:7
相关论文
共 37 条
[11]   Screening strategies for tubal factor subfertility [J].
den Hartog, J. E. ;
Lardenoije, C. M. J. G. ;
Severens, J. L. ;
Land, J. A. ;
Evers, J. L. H. ;
Kessels, A. G. H. .
HUMAN REPRODUCTION, 2008, 23 (08) :1840-1848
[12]   Standardizing Chlamydia pneumoniae assays:: Recommendations from the Centers for Disease Control and Prevention (USA) and the Laboratory Centre for Disease Control (Canada) [J].
Dowell, SF ;
Peeling, RW ;
Boman, J ;
Carlone, GM ;
Fields, BS ;
Guarner, J ;
Hammerschlag, MR ;
Jackson, LA ;
Kuo, CC ;
Maass, M ;
Messmer, TO ;
Talkington, DF ;
Tondella, ML ;
Zaki, SR ;
Bandea, C ;
Black, C ;
O'Conner, S ;
Papp, J ;
Perilla, MJ ;
Schuchat, A ;
Stevens, V ;
Van Beneden, CA ;
Zell, ER ;
Cohen, C ;
Campbell, LA ;
Wwang, SP ;
Grayston, JT ;
Deal, CD ;
Gaydos, C ;
Schindler, L ;
Taylor, CE ;
Mahony, J ;
Fong, IW ;
Leinonen, M ;
Saikku, P ;
Maas, M ;
Ossewaarde, JM ;
Persson, K ;
Boman, J ;
Apfalter, P .
CLINICAL INFECTIOUS DISEASES, 2001, 33 (04) :492-502
[13]   Chlamydia trachomatis-specific heat shock proteins 60 antibodies can serve as prognostic marker in secondary infertile women [J].
Dutta, R. ;
Jha, R. ;
Salhan, S. ;
Mittal, A. .
INFECTION, 2008, 36 (04) :374-378
[14]   Increasing chlamydia positivity in women screened in family planning clinics: Do we know why? [J].
Fine, David ;
Dicker, Linda ;
Mosure, Debra ;
Berman, Stuart .
SEXUALLY TRANSMITTED DISEASES, 2008, 35 (01) :47-52
[15]   Use of a commercial assay for detecting the 60 kDa chlamydial heat shock protein in a range of patient groups [J].
Gazzard, CM ;
Wood, RN ;
Debattista, J ;
Allan, JA ;
Allan, JM ;
Timms, P .
SEXUALLY TRANSMITTED DISEASES, 2006, 33 (02) :77-79
[16]   Comparison of a new commercial EIA kit and the microimmunofluorescence technique for the determination of IgG and IgA antibodies to Chlamydia pneumoniae [J].
Gnarpe, J ;
Nääs, J ;
Lundbäck, A .
APMIS, 2000, 108 (12) :819-824
[17]   Comparison of the new InoDiag automated fluorescence multiplexed antigen microarray to the reference technique in the serodiagnosis of atypical bacterial pneumonia [J].
Gouriet, F. ;
Levy, P. -Y. ;
Samson, L. ;
Drancourt, M. ;
Raoult, D. .
CLINICAL MICROBIOLOGY AND INFECTION, 2008, 14 (12) :1119-1127
[18]   Multiplexed whole bacterial antigen microarray, a new format for the automation of serodiagnosis: the culture-negative endocarditis paradigm [J].
Gouriet, F. ;
Samson, L. ;
Delaage, M. ;
Mainardi, J. -L. ;
Meconi, S. ;
Drancourt, M. ;
Raoult, D. .
CLINICAL MICROBIOLOGY AND INFECTION, 2008, 14 (12) :1112-1118
[19]   Multiplexed serology in atypical bacterial pneumonia [J].
Gouriet, Frederique ;
Drancourt, Michel ;
Raoult, Didier .
CENTURY OF RICKETTSIOLOGY: EMERGING, REEMERGING RICKETTSIOSES, MOLECULAR DIAGNOSTICS, AND EMERGING VETERINARY RICKETTSIOSES, 2006, 1078 :530-540
[20]   Measurement of IgG antibodies to Chlamydia trachomatis by commercial enzyme immunoassays and immunofluorescence in sera from pregnant women and patients with infertility, pelvic inflammatory disease, ectopic pregnancy, and laboratory diagnosed Chlamydia psittaci/Chlamydia pneumoniae infection [J].
Jones, CS ;
Maple, PAC ;
Andrews, NJ ;
Paul, ID ;
Caul, EO .
JOURNAL OF CLINICAL PATHOLOGY, 2003, 56 (03) :225-229