Two-point calibration procedure of the forced oscillation technique

被引:3
作者
Desager, KN [1 ]
Cauberghs, M [1 ]
Van de Woestijne, KP [1 ]
机构
[1] UZ Gasthuisberg, Lab Pneumol, Louvain, Belgium
关键词
calibration procedure; forced oscillation technique;
D O I
10.1007/BF02510989
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
The forced oscillation technique is usually calibrated by loading the measuring device with a known impedance. A correction function is calculated, relating the measured and reference impedances at each frequency. However, this one point calibration procedure does not account for transducer asymmetry. A procedure has previously been presented to circumvent this problem: in addition to one known reference impedance, the calibration was repeated with the system occluded (infinite impedance). The aim of the present study was to evaluate a variant of this procedure, in which instead of resorting to an extreme condition imposing high requirements on the flow measuring system, two reference loads of 4 and 50 hPal(-1) s were measured, thus covering the range of impedances observed in children and infants (a two-point procedure). The calibration procedure was performed with these two impedances and evaluated with a third impedance of similar to 17hPal(-1) s. The results of three calibration procedures were compared: one-point, two-point and a previously reported calibration procedure. Impedances consisted of sintered glass and mesh wire screens mounted in glass or polyvinyl tubes. For low impedance values, in the range of 4 to 17hPal(-1) s, measured and predicted values were similar for the three calibration procedures at frequencies from 4-52 Hz, although with the one point calibration procedure there was some underestimation above 44 Hz. With the highest load, especially above 32 Hz, marked discrepancies between measured and predicted values were observed with the one-point calibration procedure and the previously reported calibration procedure. Under these circumstances the two-point procedure is preferred.
引用
收藏
页码:752 / 756
页数:5
相关论文
共 12 条
[1]
CAUBERGHS M, 1991, EUR RESPIR REV, V1, P158
[2]
DELAVAULT A, 1980, RESP PHYSL, V40, P107
[3]
MEASUREMENT OF TOTAL RESPIRATORY IMPEDANCE IN INFANTS BY THE FORCED OSCILLATION TECHNIQUE [J].
DESAGER, KN ;
BUHR, W ;
WILLEMEN, M ;
VANBEVER, HP ;
DEBACKER, W ;
VERMEIRE, PA ;
LANDSER, FJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (02) :770-776
[4]
OSCILLATION MECHANICS OF LUNGS AND CHEST IN MAN [J].
DUBOIS, AB ;
BRODY, AW ;
LEWIS, DH ;
BURGESS, BF .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 8 (06) :587-594
[5]
Duvivier C., 1991, EUR RESPIR REV, V1, P146
[6]
A CORRECTION PROCEDURE FOR THE ASYMMETRY OF DIFFERENTIAL PRESSURE TRANSDUCERS IN RESPIRATORY IMPEDANCE MEASUREMENTS [J].
FARRE, R ;
NAVAJAS, D ;
PESLIN, R ;
ROTGER, M ;
DUVIVIER, C .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) :1137-1140
[7]
SYSTEMATIC AND RANDOM ERRORS IN THE DETERMINATION OF RESPIRATORY IMPEDANCE BY MEANS OF THE FORCED OSCILLATION TECHNIQUE - A THEORETICAL-STUDY [J].
FRANKEN, H ;
CLEMENT, J ;
VANDEWOESTIJNE, KP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (10) :642-651
[8]
TECHNIQUE FOR MEASURING FREQUENCY-RESPONSE OF PRESSURE, VOLUME, AND FLOW TRANSDUCERS [J].
JACKSON, AC ;
VINEGAR, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (02) :462-467
[9]
NEW METHOD TO DETERMINE FREQUENCY-CHARACTERISTICS OF RESPIRATORY SYSTEM [J].
LANDSER, FJ ;
NAGELS, J ;
DEMEDTS, M ;
BILLIET, L ;
VANDEWOESTIJNE, KP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (01) :101-106
[10]
IN-PHASE REJECTION REQUIREMENTS FOR MEASURING RESPIRATORY INPUT IMPEDANCE [J].
PESLIN, R ;
JARDIN, P ;
DUVIVIER, C ;
BEGIN, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (03) :804-809