Characterization of the acidity of residual silanol groups in microparticulate and monolithic reversed-phase columns

被引:30
作者
Herrero-Martínez, JM [1 ]
Méndez, A [1 ]
Bosch, E [1 ]
Rosés, M [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
monolithic columns; stationary phases; LC; acidity; pK(a); silanol activity;
D O I
10.1016/j.chroma.2004.04.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The residual silanol acidity and activity of several microparticulate and monolithic C 18 columns has been measured from the retention of LiNO3 in the columns with a methanol/buffer (1 mM in Na+) (60:40 v/v) mobile phase buffered to different pH values. For Luna C-18 (2) and LiChrospher RP-18 columns, at least two different types of silanols with different acidity for each packing, were observed. Purospher RP-18e and Chromolith RP-18e packings present evidence of some active silanols only at pH values close to their basic pH stability limit or higher. The results obtained have been compared with those obtained previously for Resolve C 18, Resolve Silica, Symmetry C18, Symmetry Silica, XTerra MSC18 and Underivatized XTerra. A modification of an equation previously proposed has been applied to all columns studied and the results obtained have been used to classify the columns according to their silanol acidity and activity. The method allows the prediction of the extent of the silanol activity of the columns studied at a particular mobile phase pH. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 145
页数:11
相关论文
共 38 条
[1]   Inertness and stability of newly developed wide-pore bonded silica gels [J].
Arora, R ;
Ahmed, F ;
Rustamov, I ;
Babusis, D ;
Hanai, T ;
Arora, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (18) :2763-2780
[2]   Procrustes analysis for the comparison of test methods in reversed-phase high performance liquid chromatography of basic compounds [J].
Brereton, RG ;
McCalley, DV .
ANALYST, 1999, 124 (03) :227-238
[3]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[4]   Retention of ionizable compounds on HPLC.: 4.: Mobile-phase pH measurement in methanol/water [J].
Canals, I ;
Portal, JA ;
Bosch, E ;
Rosés, M .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1802-1809
[5]   Retention of ionizable compounds on HPLC.: 6.: pH measurements with the glass electrode in methanol-water mixtures [J].
Canals, I ;
Oumada, FZ ;
Rosés, M ;
Bosch, E .
JOURNAL OF CHROMATOGRAPHY A, 2001, 911 (02) :191-202
[6]   THE INFLUENCE OF SILICA STRUCTURE ON REVERSED-PHASE RETENTION [J].
COX, GB .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :353-367
[7]   STUDY OF THE RETENTION MECHANISMS FOR BASIC COMPOUNDS ON SILICA UNDER PSEUDO-REVERSED-PHASE CONDITIONS [J].
COX, GB ;
STOUT, RW .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :315-336
[8]   Retention of ionizable compounds on HPLC.: 5.: pH scales and the retention of acids and bases with acetonitrile-water mobile phases [J].
Espinosa, S ;
Bosch, E ;
Rosés, M .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5193-5200
[9]   Designing monolithic double-pore silica for high-speed liquid chromatography [J].
Ishizuka, N ;
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :133-137
[10]   Bidentate silane stationary phases for reversed phase high-performance liquid chromatography [J].
Kirkland, JJ ;
Adams, JB ;
van Straten, MA ;
Claessens, HA .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4344-4352