Procrustes analysis for the comparison of test methods in reversed-phase high performance liquid chromatography of basic compounds

被引:6
作者
Brereton, RG
McCalley, DV
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
[2] Univ W England, Fac Sci Appl, Bristol BS16 1QY, Avon, England
关键词
D O I
10.1039/a808537d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dataset consisting of three column performance parameters obtained by testing eight reversed-phase HPLC columns with nine basic compounds and three mobile phases (methanol, acetonitrile and tetrahydrofuran) was assessed using chemometrics. The main aim was to investigate loss of information as the number of tests is reduced. Principal components analysis was performed on a full dataset using methanol as a mobile phase and procrustes analysis was used to compare numerically the scores plots as test compounds and individual test parameters were removed from the full dataset. The scores plots using different mobile phases were compared to determine whether the performance under one condition could predict that under another.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 12 条
[1]   Evaluation procedures for reversed-phase high-performance liquid chromatographic columns in the analysis of strongly basic compounds using principal components analysis for data assessment [J].
Brereton, RG ;
McCalley, DV .
ANALYST, 1998, 123 (06) :1175-1185
[2]   Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography [J].
Claessens, HA ;
van Straten, MA ;
Cramers, CA ;
Jezierska, M ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :135-156
[3]   THE INFLUENCE OF SILICA STRUCTURE ON REVERSED-PHASE RETENTION [J].
COX, GB .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :353-367
[4]   Procrustes analysis for the determination of number of significant masses in gas chromatography mass spectrometry [J].
Demir, C ;
Hindmarch, P ;
Brereton, RG .
ANALYST, 1996, 121 (10) :1443-1449
[5]   Chemometric analysis of high performance liquid chromatography diode array detection electrospray mass spectrometry of 2- and 3-hydroxypyridine [J].
Dunkerley, S ;
Crosby, J ;
Brereton, RG ;
Zissis, KD ;
Escott, RE .
ANALYST, 1998, 123 (10) :2021-2033
[6]  
Jolliffe I. T., 1986, PRINCIPAL COMPONENT, DOI DOI 10.1007/978-1-4757-1904-87
[7]  
Leach D.C., 1988, LC GC INT MAG LIQ GA, V1, P22
[8]   Effect of organic solvent modifier and nature of solute on the performance of bonded silica reversed-phase columns for the analysis of strongly basic compounds by high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1996, 738 (02) :169-179
[9]   High-performance liquid chromatography of basic compounds - Problems, possible solutions and tests of reversed-phase columns [J].
McCalley, DV ;
Brereton, RG .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :407-420
[10]   Comparative evaluation of bonded-silica reversed-phase columns for high-performance liquid chromatography using strongly basic compounds and alternative organic modifiers buffered at acid pH [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :169-178