Effect of organic solvent modifier and nature of solute on the performance of bonded silica reversed-phase columns for the analysis of strongly basic compounds by high-performance liquid chromatography

被引:96
作者
McCalley, DV
机构
[1] Dept. of Chem. and Physical Sciences, University of the West of England, Frenchay
关键词
mobile phase composition; stationary phases; LC; organic modifiers; basic compounds;
D O I
10.1016/0021-9673(96)00136-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of eight silica-based RP-HPLC columns was examined with nine relatively high-pit, bases of different structure using isoeluotropic mixtures of either methanol, acetonitrile or tetrahydrofuran (THF) in combination with phosphate buffer pH 7.0. Meaningful evaluation of the columns in unbuffered methanol-water and acetonitrile-water mixtures could only be obtained for low-pK(a) bases, probably due to variable ionisation effects. Buffered acetonitrile generally produced worst peak shapes for the nine higher-pK(a) bases; further improvement may be gained in some cases using THF rather than methanol. Although in general high-pK(a) solutes with reduced steric hindrance gave the most asymmetric peaks, the nature of the solute chosen to probe activity could give considerably different results of relative column performance when using a given mobile phase.
引用
收藏
页码:169 / 179
页数:11
相关论文
共 19 条
[1]  
Albert A., 1984, DETERMINATION IONISA
[2]   SEPARATION OF ORGANIC AMINE COMPOUNDS ON SILICA-GEL WITH REVERSED-PHASE ELUENTS [J].
BIDLINGMEYER, BA ;
DELRIOS, JK ;
KORPI, J .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :442-447
[3]   DEUTERIUM NUCLEAR-MAGNETIC-RESONANCE SPECTROSCOPY AS A PROBE FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHIC BONDED PHASE SOLVATION .2. AQUEOUS SOLVATION IN METHANOL AND ACETONITRILE BINARY MOBILE PHASES [J].
BLIESNER, DM ;
SENTELL, KB .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :1819-1826
[4]  
CLAESSENS HA, 1993, LC GC EUR, V6, P692
[5]  
Dean J.A., 1985, LANGES HDB CHEM, V13
[6]   COMPARISON AND CHARACTERIZATION OF REVERSED PHASES [J].
ENGELHARDT, H ;
JUNGHEIM, M .
CHROMATOGRAPHIA, 1990, 29 (1-2) :59-68
[7]   STUDY OF THE EXCESS ADSORPTION OF THE ELUENT COMPONENTS ON DIFFERENT REVERSED-PHASE ADSORBENTS [J].
KAZAKEVICH, YV ;
MCNAIR, HM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (06) :321-327
[8]   HIGH PH MOBILE-PHASE EFFECTS ON SILICA-BASED REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
KIRKLAND, JJ ;
VANSTRATEN, MA ;
CLAESSENS, HA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :3-19
[9]  
KIRKLAND JJ, 1995, HPLC 95 INNSBR JUN
[10]  
Leach D.C., 1988, LC GC INT MAG LIQ GA, V1, P22