Selective and Graded Recruitment of Cat Hamstring Muscles With Intrafascicular Stimulation

被引:18
作者
Dowden, Brett R. [1 ]
Wilder, Andrew M. [2 ]
Hiatt, Scott D. [3 ]
Normann, Richard A. [1 ]
Brown, Nicholas A. T. [1 ,4 ]
Clark, Gregory A. [1 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Sch Comp, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
[4] Univ Utah, Dept Orthopaed, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Feline hamstring muscles; intrafascicular stimulation; motor neuroprosthesis; neuromuscular stimulation; selective activation; FUNCTIONAL ELECTRICAL-STIMULATION; NERVE CUFF ELECTRODE; BICEPS FEMORIS; SCIATIC-NERVE; ACTIVATION; ARRAY; WALKING; FIBERS; TISSUE;
D O I
10.1109/TNSRE.2008.2011988
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The muscles of the hamstring group can produce different combinations of hip and knee torque. Thus, the ability to activate the different hamstring muscles selectively is of particular importance in eliciting functional movements such as stance and gait in a person with spinal cord injury. We investigated the ability of intrafascicular stimulation of the muscular branch of the sciatic nerve to recruit the feline hamstring muscles in a selective and graded fashion. A Utah Slanted Electrode Array, consisting of 100 penetrating microelectrodes, was implanted into the muscular branch of the sciatic nerve in six cats. Muscle twitches were evoked in the three compartments of biceps femoris (anterior, middle, and posterior), as well as semitendinosus and semimembranosus, using pulse-width modulated constant-voltage pulses. The resultant compound muscle action potentials were recorded using intramuscular fine-wire electrodes. 74% of the electrodes per implant were able to evoke a threshold response in these muscles, and these electrodes were evenly distributed among the instrumented muscles. Of the five muscles instrumented, on average 2.5 could be selectively activated to 90% of maximum EMG, and 3.5 could be selectively activated to 50% of maximum EMG. The muscles were recruited selectively with a mean stimulus dynamic range of 4.14 +/- 5.05 dB between threshold and either spillover to another muscle or a plateau in the response. This selective and graded activation afforded by intrafascicular stimulation of the muscular branch of the sciatic nerve suggests that it is a potentially useful stimulation paradigm for eliciting distinct forces in the hamstring muscle group in motor neuroprosthetic applications.
引用
收藏
页码:545 / 552
页数:8
相关论文
共 28 条
[1]   Stimulation parameter optimization for FES supported standing up and walking in SCI patients [J].
Bijak, M ;
Rakos, M ;
Hofer, C ;
Mayr, W ;
Strohhofer, M ;
Raschka, D ;
Kern, H .
ARTIFICIAL ORGANS, 2005, 29 (03) :220-223
[2]   A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats [J].
Branner, A ;
Normann, RA .
BRAIN RESEARCH BULLETIN, 2000, 51 (04) :293-306
[3]   Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes [J].
Branner, A ;
Stein, RB ;
Normann, RA .
JOURNAL OF NEUROPHYSIOLOGY, 2001, 85 (04) :1585-1594
[4]   Clinical experience with functional electrical stimulation-assisted gait with parastep in spinal cord-injured patients [J].
Brissot, R ;
Gallien, P ;
Le Bot, MP ;
Beaubras, A ;
Laisné, D ;
Beillot, J ;
Dassonville, J .
SPINE, 2000, 25 (04) :501-508
[5]   Mechanical actions of compartments of the cat hamstring muscle, biceps femoris [J].
Carrasco, DI ;
English, AW .
PERIPHERAL AND SPINAL MECHANISMS IN THE NEURAL CONTROL OF MOVEMENT, 1999, 123 :397-403
[6]  
Davis JA, 2001, J REHABIL RES DEV, V38, P609
[7]   AN ANATOMICAL AND FUNCTIONAL-ANALYSIS OF CAT BICEPS FEMORIS AND SEMITENDINOSUS MUSCLES [J].
ENGLISH, AW ;
WEEKS, OI .
JOURNAL OF MORPHOLOGY, 1987, 191 (02) :161-175
[8]   Quantification of recruitment properties of multiple contact cuff electrodes [J].
Grill Jr., W.M. ;
Mortimer, J.T. .
IEEE Transactions on Rehabilitation Engineering, 1996, 4 (02) :49-62
[9]   The effect of stimulus pulse duration on selectivity of neural stimulation [J].
Grill, WM ;
Mortimer, JT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (02) :161-166
[10]  
HIATT SD, 2007, BIOM ENG SOC C