The objective of this study was to assess the use of temporary stenting of the prostatic urethra for the prevention of acute rinary retention after high-energy, transurethral microwave thermotherapy (TUMT) of the prostate. Stenting was performed immediately after high-energy microwave therapy. Two stents were used at two sites, at one site a silicone transurethral prostatic bridge was used in 42 patients, and at the second site a self-reinforced polyglycolic acid (SR-PGA) biodegradable spiral was used in 16 patients. Patients were scheduled for TUMT for symptomatic benign prostatic hyperplasia. Preoperative investigations included determination of a symptom score, measurement of the peak flow rate, and determination of the voided volume. The patients were treated using the Prostatron TUMT system. The software used provided a maximal power output of 70 W. After 1 week as well as 1, 3, 6, and 12 months the measurements were repealed and the effect of the stents was assessed. The symptom score, peak flow rate, and voided volume showed a significant improvement. Improvement was observed at first visit and sustained during the follow-up. Prophylaxis of acute urinary retention after TUMT can easily be managed by temporary stenting of the prostatic urethra. Temporary stenting can be routinely proposed after high-energy TUMT of the prostate.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 13 条
[1]   TRANSURETHRAL MICROWAVE THERMOTHERAPY VERSUS TRANSURETHRAL RESECTION FOR SYMPTOMATIC BENIGN PROSTATIC OBSTRUCTION - A PROSPECTIVE RANDOMIZED STUDY WITH A 2-YEAR FOLLOW-UP [J].
DAHLSTRAND, C ;
WALDEN, M ;
GEIRSSON, G ;
PETTERSSON, S .
BRITISH JOURNAL OF UROLOGY, 1995, 76 (05) :614-618
[2]  
DAHLSTRAND C, 1998, IN PRESS BR J UROL, V79
[3]  
DAHLSTRAND C, 1995, J UROL S4, V153, pA824
[4]  
DELAROSETTE J, 1995, J UROL S4, V153, pA822
[5]  
DEVONEC M, 1995, CURR OPIN UROL, V5, P3
[6]  
Devonec Marian, 1997, Journal of Urology, V157, P436
[7]   A BIORESORBABLE URETHRAL STENT - AN EXPERIMENTAL-STUDY [J].
KEMPPAINEN, E ;
TALJA, M ;
RIIHELA, M ;
POHJONEN, T ;
TORMALA, P ;
ALFTHAN, O .
UROLOGICAL RESEARCH, 1993, 21 (03) :235-238
[8]   THE INTRAPROSTATIC SPIRAL - CLINICAL-RESULTS IN 150 CONSECUTIVE PATIENTS [J].
NORDLING, J ;
OVESEN, H ;
POULSEN, AL .
JOURNAL OF UROLOGY, 1992, 147 (03) :645-647
[9]  
PARIKH AM, 1995, EUR UROL, V27, P1
[10]   The biodegradable self-reinforced poly-DL-lactic acid spiral stent compared with a suprapubic catheter in the treatment of post-operative urinary retention after visual laser ablation of the prostate [J].
Petas, A ;
Talja, M ;
Tammela, TLJ ;
Taari, K ;
Valimaa, T ;
Tormala, P .
BRITISH JOURNAL OF UROLOGY, 1997, 80 (03) :439-443