Magnetic resonance imaging of articular cartilage of the knee: Comparison between fat-suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy

被引:120
作者
Yoshioka, H
Stevens, K
Hargreaves, BA
Steines, D
Genovese, M
Dillingham, MF
Winalski, CS
Lang, P
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Sch Med, Dept Elect Engn, Stanford, CA 94305 USA
[4] Stanford Univ, Sch Med, Dept Immunol & Rheumatol, Stanford, CA 94305 USA
[5] SOAR Med Associates, Menlo Pk, CA USA
关键词
MRI; cartilage; arthroscopic correlation; FSE; SPGR; DEFT;
D O I
10.1002/jmri.20193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare signal-to-noise ratios (S/N) and contrast-to-noise ratios (C/N) in various MR sequences, including fat-suppressed three-dimensional spoiled gradient-echo (SPGR) imaging, fat-suppressed fast spin echo (FSE) imaging, and fat-suppressed, three-dimensional driven equilibrium Fourier transform (DEFT) imaging, and to determine the diagnostic accuracy of these imaging sequences for detecting cartilage lesions in. osteoarthritic knees, as compared with arthroscopy. Materials and Methods: Two sagittal fat-suppressed FSE images (repetition time [TR] / echo time [TE], 4000/13 [FSE short TE] and 4000/39 [FSE long TE]), sagittal fat-suppressed three-dimensional SPGR images (60/5, 40degrees flip angle), and sagittal fat-suppressed echo-planar three-dimensional DEFT images (400/21.2) were acquired in 35 knees from 28 patients with osteoarthritis of the knee. The S/N efficiencies (S/Neffs) of cartilage, synovial fluid, muscle, meniscus, bone marrow, and fat tissue, and the C/N efficiencies (C/Neffs) of these structures were calculated. Kappa values, exact agreement, sensitivity, specificity, positive predictive value, and negative predictive value were determined by comparison of MR grading with arthroscopic results. Results: The synovial fluid S/Neff on fat-suppressed FSE short TE images, fat-suppressed-FSE long TE images, and fat-suppressed, three-dimensional DEFT images showed similar values. Fat-suppressed three-dimensional DEFT images showed the highest fluid-cartilage C/Neff of all sequences. All images showed fair to good agreement with arthroscopy (kappa, 0.615 in FSE short TE, 0.601 in FSE long TE, 0.583 in three-dimensional SPGR, and 0.561 in three-dimensional DEFT). Although the sensitivity of all sequences was high (100% in FSE short TE, FSE long TE, and DEFT; 96.7% in SPGR), specificity was relatively low (67.6% in FSE short TE and FSE long TE; 85.3% in SPGR; 58.3% in DEFT). The peripheral area of bone marrow edema or whole area of bone marrow edema on fat-suppressed FSE images was demonstrated-as low or iso-signal intensity on fat-suppressed three-dimensional DEFT images. Conclusion: Fat-suppressed. three-dimensional SPGR imaging and fat-suppressed FSE imaging showed high sensitivity and high negative predictive values, but relatively low specificity. The Kappa value and exact agreement was the highest, on fat-suppressed FSE short TE images. Fat-suppressed three-dimensional, DEFT images showed results similar to-the conventional sequences. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:857 / 864
页数:8
相关论文
共 29 条
[1]  
AYRAL X, 1994, REV RHUM, V61, P97
[2]   Glycosaminoglycan in articular cartilage: In vivo assessment with delayed Gd(DTPA)(2-)-enhanced MR imaging [J].
Bashir, A ;
Gray, ML ;
Boutin, RD ;
Burstein, D .
RADIOLOGY, 1997, 205 (02) :551-558
[3]   Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[4]   SEVERITY OF ARTICULAR-CARTILAGE ABNORMALITY IN PATIENTS WITH OSTEOARTHRITIS - EVALUATION WITH FAST SPIN-ECHO MR VS ARTHROSCOPY [J].
BRODERICK, LS ;
TURNER, DA ;
RENFREW, DL ;
SCHNITZER, TJ ;
HUFF, JP ;
HARRIS, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :99-103
[5]   MR imaging of articular cartilage [J].
Disler, DG ;
Recht, MP ;
McCauley, TR .
SKELETAL RADIOLOGY, 2000, 29 (07) :367-377
[6]   Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: Assessment of articular and physeal hyaline cartilage [J].
Disler, DG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) :1117-1123
[7]   DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY [J].
DISLER, DG ;
MCCAULEY, TR ;
WIRTH, CR ;
FUCHS, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :377-382
[8]   Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy [J].
Disler, DG ;
McCauley, TR ;
Kelman, CG ;
Fuchs, MD ;
Ratner, LM ;
Wirth, CR ;
Hospodar, PP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :127-132
[9]   FAT-SUPPRESSED SPOILED GRASS IMAGING OF KNEE HYALINE CARTILAGE - TECHNIQUE OPTIMIZATION AND COMPARISON WITH CONVENTIONAL MR-IMAGING [J].
DISLER, DG ;
PETERS, TL ;
MUSCOREIL, SJ ;
RATNER, LM ;
WAGLE, WA ;
COUSINS, JP ;
RIFKIN, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :887-892
[10]  
Hargreaves BA, 1999, MAGN RESON MED, V42, P695, DOI 10.1002/(SICI)1522-2594(199910)42:4<695::AID-MRM11>3.0.CO